KU3241 Installation KU3241 User Manual 1
KU3241 Installation Content 1 KU3241 Specification P3 2 3 4 5 6 7 8 KU324 Product Components Safety Note How It Work Power Supply Connection Tube Connection Running Test System Assembly and Completion 8-1 Completion 8-2 Maintenance 8-3 Trouble shooting Warranty 9-1 Coverage 9-2 Warranty Conditions P3 P4 P4 P5 P5-6 P7 9 2 P8 P8 P9 P10 P10
KU3241 Installation 1.Specifications: Heat Exchange Radiator 1) Dimension: 310(L)X 124(W)X 35(H)mm 2) Weight:680g 3) Material: Copper tube and aluminum fin 4) Fan Speed: 1200 RPM(7V)-1500 RPM(12V) 5) Operating Temperature: 0℃~40℃ CPU Water-Block 1) Dimension: 60(L) X 54(W) X 14(H)mm 2) Material: Copper 3) Weight:330g 4) Application: PUMP 1) Dimension: 119.2(L) X 78(W) X 117.4(H)mm 2) Power Consumption:10.8W 3) Operating Voltage:DC 12V 4) Flow Rate:450L/Hr 5) Max. Water Lift:2.
KU3241 Installation 3. Safety Notes 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) Read this instruction carefully before installing and running this product. If you are new to the water cooling system, we suggest you ask for help. Please disconnect all powers of the computer before installing this product. Please note all safety issues common with all electronics to avoid damages. The product is suitable for home or office use only, no other special applications, such as medical are allowed.
KU3241 Installation 5.Power Supply Connection: -STEP1- z Remove side panel, threat fan wiring as shown on picture, screws on I/O bracket until locked in. -STEP2- z Connect the fan wiring with power supply. -STEP3- z Connect the pump connector cable onto the computer. 6.Tube Connection: 1. Determine the length of the tube required between the Water-Blocks before cutting and connecting the water lines. 2.
KU3241 Installation -STEP1- z First, set in the clamp on one end of the tube, connect the tube with tubing adapter, and use pliers to move the clamp onto proper location. -STEP2- z -STEP3- z Allow the two internally connected tubes to go through the holes on the back of the housing. Connect the pump tubing adapter with the tube, use pliers to move the clamp onto proper location.
KU3241 Installation 7.Running Test: Please disconnect all powers inside the main frame (including hard drives and CD-ROM). Test Run the system for 20 mines, check if all parts are correctly connected. -STEP1- z Insert ATX jumper wire into the 4th and 6th socket of the power supply connector of ATX-motherboard. -STEP2- z Loosen the nozzle socket plug of the reservoir; pour in some coolant to the water tank. -STEP3- z Press the power button to start.
KU3241 Installation 8. Completing The System Installation: 8-1 Completion z After system test run is complete, you can start using the KU3241 water cooling system.Before starting the computer, remove ATX jumper from the ATX-Main Frame power sockets, 8-2. Maintenance: We value the reliability and convenience during the development of this product, however you would still need to note the following: 1.
KU3241 Installation 8-3. Trouble Shooting We list the common issues and their solutions as follows, if there is a system problem, please refer below. If the issues persist, contact us for technical support. Common Issue Solution Water line leakage ●Check if all connections are locked tight. ●Check if water line is plugged in correctly, and all bolts and screws are tightly locked in. Mother board water splash ●Dry the mother board for 8-12 hrs, or blow dry the mother board.
KU3241 Installation 9. Warranty: 9-1 Coverage: Larkooler values the quality and safety of our products, and strict quality control measures are in place. Within one (1) year of purchase is our warranty period, if you encounter any issues during such time, a free service will be carried out.