Datasheet

This standalone data logger can record events (detecting an input and storing the time and date), record state changes (similar to an ‘event’
but also recording when the input reverts back to normal) and count events (count the number of events that happen during a timed interval).
Up to 32,510 events or state changes can be recorded and up to 32,510 timed intervals in event counter mode (with 65,536 events in each
interval).
Events and state changes can be triggered by either a rising edge (a voltage going from low to high) or falling edge (a voltage going from high
to low). It is also possible to use volt free contacts. Instead of measuring an external voltage, the data logger applies a voltage across the
screw terminals and detects when the input closes (i.e. a relay or microswitch).
Fast logging rates allow event capturing at speeds of up to two times per second and state changes at speeds of up to four times per second.
Event counting can operate at speeds of up to 100 times per second (when the LEDs are turned off). The user can easily set up the logger,
and download the stored data by plugging the data logger into a PC’s USB port and running the purpose designed software under Windows
2000, XP, Vista & 7. Data can then be graphed, printed and exported to other applications.
The data logger is supplied complete with software, measurement leads terminated with crocodile clips and a long-life lithium battery which
allows logging for up to 1 year. Functionality of the unit is indicated by ashing red and green LEDs, with an option to ash the red LED every
time an event occurs.
EL-USB-5
Counter, Event and State
USB Data Logger
FEATURES
Functions as an event logger, state change logger and event counter
Logging rate of up to four times per second for events, two times per
second for state changes and 100 times per second when counting
Stores up to 32,510 readings in event mode
Stores up to 32,510 readings in state change mode
Stores up to 32,510 timed intervals in event counter mode
Accepts input voltages of up to 24V
Volt free contacts option (normally open contact only)
Rising and falling edge triggering
LED ash on event / state change
Connection via two screw terminals
USB Interface for set-up and data download
Supplied with replaceable internal lithium battery, Windows
control software and measurement leads
ORDERING INFORMATION
Standard Data Logger
(Data Logger, Software on
CD, Battery)
Replacement Battery
EL-USB-5
BAT 3V6 1/2AA
www.lascarelectronics.com
* 10 milliseconds can only be achieved with the LEDs disabled. If the LEDs are enabled, the time between the event counts is reduced to 50 milliseconds
** see ‘Voltage input range’ section for details
*** Voltage will decrease as battery is discharged
† Per day at 20ºC
‡ Assuming 1 event every 5 mins at 20ºC in Voltage input mode
Specications liable to change without prior warning Issue 4 01/11 S.L Applies to EL-USB-5 Page 1 of 5
Specications Minimum Typical Maximum Unit
Time between events 200 Milliseconds
Time between state changes 500 Milliseconds
Time between event counts 10* Milliseconds
Input voltage ** 3 28 V d.c.
‘Volt free contacts’ voltage *** 2.75 3.6 V
‘Volt free contacts’ current 35 μA
Timing accuracy † ±3 Seconds per 24 hours
Operating temperature range -35 (-31) +80 (176) ºC (ºF)
1/2AA 3.6V Lithium Battery Life 1 Years