Instructions

DampFinder Home
13
EN
Functional and operational safety is only warranted when the
instrument is operated within the specied climatic conditions
and is only used for those purposes for which it is designed.
The assessment of measurement results and actions taken
as a consequence lie in the user‘s scope of responsibility,
depending on the given type of work.
!
Subject to technical changes without notice. 19W09
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=daho
Technical data
Measurement principle
Resistive material moisture measurement
by way of integrated electrodes
Modes
2 wood groups
3 building materials
Test mode
Materials /
Measurement range
Cement screed: 1% ... 4,5%
Gypsum plaster: 0.1% ... 38.2%
Cellular concrete: 2.2% ... 99%
Wood: 5% ... 99%
Accuracy (absolute)
Wood: ± 1% (5% … 30%)
± 2% (<5% and >30%)
± 0.15% (0% ... 10%)
± 1% (>10%)
Operating conditions
C…40°C, Max. humidity 85% rH,
no condensation, Max. working
altitude 2000 m above sea level
Storage conditions -10°C…50°C, Max. humidity 85% rH
Power supply
1 x 6LR61, 9V
Dimensions (W x H x D) 57 x 120 x 44 mm
Weight (incl. battery) 146 g
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning
agents, scouring agents and solvents. Remove the battery(ies) before
storing for longer periods. Store the device in a clean and dry place.