User manual

0.93 0.93
2 m 2 m
0.0 °C 0.0 °C
Point 1
Point 2
Point 3
Point 1
Point 2
Point 3
Manual
Max
Min
Point 1
Point 2
Point 3
Point 1
Point 2
Point 3
Mode Point 1
Use global para
Emiss:
Distan:
Offset:
Use global para
Emiss:
Distan:
Offset:
Settings Point 1 Settings Point 1
ThermoCamera-Vision
10.0
10.1
10.2
37
GB
Activate / deactivate measurement points
Measurement points / function
Measurement points / parameters
activated deactivated
Point 1
Point 2
Point 3
activated deactivated
Manual
Max.
Min.
Up to three measurement points can be set at one time. They can be assigned measurement-speciÖ c
parameters as well as the following properties: maximum temperature, minimum temperature, manual
positioning.
For each measurement point, you can either use the previously set general parameters (see chapter 8)
or deÖ ne different parameters.
To set values that deviate from the general parameters, deactivate the check for the general
parameters in this menu.
!
Manual: The measurement
point position is determined by
moving it on the touch screen.
Min. / Max.: The measurement
point is shown in the thermo-
gram with the minimum/
maximum temperature.
Manual_ThermoCamera_Vision_Rev.0113.indd 37 25.01.13 10:06