Instructions

09
ActiveFinder One
3
EN
The LED indicator in the detector tip (1) signals the following:
Green LED: Tester ready / off-circuit area
Red LED with alarm: Live wires in vicinity
LED off: Tester not ready
LED indicator/status indicator
EU directives and disposal
(see Fig. K)
This device complies with all necessary standards for the free movement of
goods within the EU. This product is an electric device and must be collected
separately for disposal according to the European Directive on waste electrical
and electronic equipment. Further safety and supplementary notices at:
http://laserliner.com/info?an=acfion
Technical data Subject to technical alterations. Rev18W41
Indicator LED (red/green)
Voltage range
50 V AC ~ 1000 V AC
Frequency 50 ... 60 Hz
Overvoltage category
CAT III - 1000 V (non-condensing)
Pollution degree 2
Power supply 2 x 1.5 AAA (NEDA 24A/IEC LR 03)
Operating conditions
0°C ... 50°C, Max. humidity 80% rH,
no condensation,
max. altitude 2000 m
Storage conditions
-10°C ... 60°C,
Max. humidity 80% rH
Dimensions (W x H x D) 19 x 139 x 25 mm
48 g
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Please be aware that even if a visual signal is not displayed, voltage may
still be present. Differences in the design of the connection socket or
the nature of the insulation (thickness and type) can affect functionality.
Voltage cannot be detected behind panels and metal covers.
!
For safety, check all three phase conductors (L1, L2, L3) for the presence
of voltage!
!
Change the batteries when the acoustic signal is weak.
!
4
Localising electrical voltages
Fig. G: Position the detector tip in the area to be tested (e.g. cable, socket. etc.).
Fig. H: When voltage is present, the detector tip lights red and a signal sounds.