Operation Manual

19
MultiFinder Plus
GB
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info
Subject to technical alterations. 06.2016
Technical data
Detection range AC 110 - 230V, 50 - 60 Hz
Operating temperature 0°C ... 40°C (32°F ... 104°F)
Storage temperature
-20°C ... 70°C (-4°F ... 158°F)
Power supply
1 x 9 V alkaline battery
(type 6LR 61)
Dimensions (W x H x D) 45 mm x 94 mm x 250 mm
Weight (incl. battery) 230 g
Measuring depth
Wood/metal beam location
(STUD-SCAN)
Up to 4 cm depth
Targeted metal location:
Ferro-Scan/Non-Ferro-Scan
(METAL-SCAN)
Up to 10 cm /
up to 5 cm depth
Targeted location of live
supply lines (AC-SCAN)
Up to 4 cm depth
Location of dead
supply lines
Up to 4 cm depth
Clean all components with a damp cloth and do not use cleaning
agents, scouring agents and solvents. Remove the battery(ies)
before storing for longer periods. Store the device in a clean and
dry place.
Information on maintenance and care