Operation Manual
PrecisionCross-Laser PCL 5P RXR
Universal mount:
The laser receiver RX 51 can be fitted on measuring staffs
with the universal mount. The Flexi measuring staff (Art. No.
080.50) is always recommended when measuring from floor
heights. It also allows you to determine heights directly
without any need for calculation.
ENGLISH 13
Note: Always switch the unit off before moving it (pushbutton 11, status
indicator 10 off) in order to protect it against damage.
Note: Regularly check the calibration before use, after transport and after
extended periods of storage.
Technical data
Self-levelling range + 3°
Precision + 1 mm / 10 m
Working range with laser receiver max. 50 m
Laser wavelenghts, line lasers / plumb laser 635 nm / 655 nm
Laser class / Laser output rating line lasers 2M / < 5 mW
Laser class / Laser output rating plumb laser 2 / < 1 mW
Protection class PCL 5P RXR IP 54
Power supply PCL 5P RXR (batteries) 4 x 1,5V LR6 (AA)
Power supply PCL 5P RXR (rechargeable batteries)
4 x 1,2V R6 NiMH (AA)
Operating period (rechargeable NiMH) ca. 8 h
Power supply laser receiver RX 51 1 x 9V block
Power supply for remote control 2 x 1,5V LR 03 (AAA)
Weight PCL 5P RXR 1,7 kg
Operating temperature 0°C ... + 50°C
Storage temperature -10°C ... + 70°C
Order number 039.00.00A
Subject to technical alterations 01/2008