Operation Manual
12
ENGLISH
ZipLevel
MARK
With the MARK-function you can produce tones to indicate the following
states: a) a chosen height, b) height within a defined scope or c) height
beyond a defined scope.
1) Start of this function:
Get the measuring module into the required
height and press the MARK-key for 2 seconds. Keep the unit steady
until double lines for the scope are blinking on the display and choose
a), b) or c).
a) Produce a tone at a chosen height:
Shortly press MARK and keep the unit steady to set up the tone.
b) Produce a tone
within a defined scope:
Move the measuring module half a scope under the chosen height.
Shortly press MARK and hold the unit steady to set up the tone.
c) Produce a sound
beyond a defined scope:
Move the measuring module half a scope above the chosen height.
Shortly press MARK and hold the unit steady to set up the tone.
Advice: If you want to leave the MARK-function early, shortly press MARK
and ON/OFF at the same time.
ENGLISH