ZipLevel
Quick start of the ZipLevel
Open the bottom protective cap of the basic unit and remove the measu-
ring module. Lay the basic unit on the floor with the back facing down.
Slowly pull a sufficient length of line off the cable reel. The altitude will be
transferred from the basic unit to the measuring module.
Switch the measuring module on with the ON/OFF-key and put the unit
with its back or base on the required place of reference. When the display
is ready, you will hear 2 short audible bleeps. Press the ZERO-key for 2
seconds. Keep the measuring module steady until the figure zero appears
on the display. The appliance has now been set.
ADVICE: If the basic unit gets moved, the measuring module needs to be
set at the place of reference again.