Intercom Installation Guide
Table of contents Model: INT1LFCNA1 Document number 770-00012 V1 Revised on 08/03/2020 Things you should know 04 Included in the box 05 Product details 07 Specifications 16 Installation 19 Handling information 33 Requirements for compliance 34
Things you should know Included in the Box Mounting Hardware • • • • • Latch Intercom requires a Latch R in order to operate and can only be paired with one R. Intercom installation should occur before Latch R installation. Only use screws provided. Other screws can cause Latch Intercom to disengage from the mounting plate. Configuration requires the iOS Manager App running on an iPhone 5S or newer.
Product Details Details and recommendations for power, wiring, and product specifications. 6 Intercom Installation Guide Version 1.
Product Details Direct Power Minimum wiring recommendations Distance Power < 25ft < 50ft < 100ft 12V 22 AWG 18 AWG 16 AWG 24V 24 AWG 22 AWG 18 AWG < 200ft 16 AWG 12VDC - 24VDC 50 Watts Supply* *Class 2 Isolated, UL Listed DC Power Supply Choice of Ethernet, Wi-Fi, and/or LTE connection is required 8 Intercom Installation Guide Version 1.
Wiring PoE Minimum wiring recommendations PoE Source 50W+ Distance 328ft (100m) CAT Type 5e Shield Shielded AWG 10 - 24 AWG 6 6a 7 8 *Ethernet cable recommended to meet CMP or CMR rating PoE 802.3bt 50 Watts Supply Choice of additional Wi-Fi and/or LTE connection is optional 10 Intercom Installation Guide Version 1.
Detail View of Cable RJ45 Female Type Connector 12 Intercom Installation Guide Version 1.
Product Details Mounting Plate Centerline Mark Microphone Microphone Procedural Numbers Display Centerline Mark Navigational Buttons Support Cable Hook Speaker Mesh Security Screw Note: Refer to ADA Guidelines on mounting height. 14 Intercom Installation Guide Version 1.
Specifications Dimensions Display • 12.82in (32.6cm) x 6.53in (16.6 cm) x 1.38in (3.5cm) • • • • Network • • • • • Ethernet: 10/100/1000 Bluetooth: BLE 4.2 (iOS and Android compatible) Wi-Fi: 2.4Ghz/5Ghz 802.
Installation Follow these steps to proceed with installation. 18 Intercom Installation Guide Version 1.
1. Align the center mark on the mounting plate and center on wall. Level and mark holes 1 and 2. Drill, anchor, and screw in place. 20 Intercom Installation Guide Note: Hole 2 is slotted for adjustments. Version 1.
2. Find the center of the 1.5 inch cable bore hole using marks as a guide. Temporarily remove the mounting plate and drill a 1.5 inch hole. 22 Intercom Installation Guide Drill and set anchors for remaining holes 3-6. Reinstall the mounting plate. Version 1.
3. Important: Keep the protective bumpers on. Using the support cable, hook the Intercom to the mounting plate for easier wiring. 24 Intercom Installation Guide Align pocket in the bumper with the lower mounting plate tab. Place the loop of support cable over hook. Version 1.
4a. A Female RJ45 You may use an Ethernet cable to provide both power and internet to the device. Or you may utilize the direct power wires alongside onboard Wi-Fi or cellular. 26 Intercom Installation Guide B C D Male RJ45 Connector Seal Split Gland E Cable Seal Step 1: Feed B through C and E Step 2: Plug B into A Step 3: Connect A to C by twisting. Add D behind C Step 4: Screw E into C Version 1.
4b. 5. If you’re not utilizing PoE, use crimps to connect to direct power. Unhook the support cable, remove bumpers, and feed all wires and cables through the wall. Use the center alignment pins to locate the product. Place the Latch Intercom flush with the mounting plate and slide down until all mounting tabs fit snugly. Important: Ensure cables are dry and free of moisture before connecting. 28 Intercom Installation Guide Version 1.
6. Incorrect Correct Note: We recommend forming a drip loop of cables to help avoid moisture condensation on connections or device. 30 Intercom Installation Guide Lock into place with the TR20 security screw. Version 1.
7. Important Handling Information Operating Environment Device performance may be affected if operated outside these ranges: Operating and Storage Temperature: -22°F to 140°F (-30°C to 60°C) Relative Humidity: 0% to 93% (non-condensing) Cleaning Although the device is water resistant, do not apply water or liquid directly to the device. Dampen a soft cloth to wipe the exterior of the device. Do not use solvents or abrasives that might damage or discolor the device.
Regulatory Compliance Federal Communications Commission (FCC) Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Safety Instructions (Continued) • Outdoor electrical boxes used for mounting are recommended to be NEMA 3 or better • Correct wiring insulation should be used during installation to prevent the risk of electrical shock Testing and Maintenance Operation Prior to installation, ensure that all wiring is secure.
38 Intercom Installation Guide Version 1.