Use and Care Manual

Quick Start Steps
Carefully follow each step of these instructions for a trouble-
free experience.
Note: It is recommended to install and mount the PC600 terminal
before installing the PayClock software. With the PC600 terminal
powered up and connected to the network (LAN), the software will
search for it on the network and automatically configure the terminal.
1
2
3
Select a location that will be convenient to
employees punching In/Out. Also keep in
mind that a 115vAC power outlet should
be within 6 feet as well as a connection to
the network (LAN).
For more detailed information turn to
page 7.)
Verify the contents of your system. (For
more detailed information turn to page
5.)
Use masking tape to hold the included
mounting template onto the wall. Drill
the holes using the template as a guide.
Note: The bottom of the terminal
should be about 45 inches from the
floor.
Remove the template and install the
mounting screws, using the plastic wall
anchors if needed. Leaving about 3/16”
of the screw exposed.