Appendix A - PC600 WAN Installation
These instructions identify the steps to configure the PC600 terminal
to communicate with the PayClock database server across the
internet.
A print out of the “Server Summary” information is required for this
set up. If the information was not printed during the PayClock
software installation follow these steps to access the information.
• At the computer where the PayClock database server resides,
open the PayClock software.
• Click the PayClock orb on the upper left and from the menu,
select Support Assistant.
• In the Support Assistant window select
Connection Info
.
• Print the Connection_Info.txt file for use when configuring
the PC600.
WAN Installation Requirements
• There must be a VPN tunnel connecting the local and remote
sites.
• A static IP address is required on the computer designated as
the PayClock database server.
• A network administrator may be required to configure the
network routers to route the ports used by the PC600
terminals and PayClock database server.
Important Port Information - The following ports are used for this
type of installation.
• 7350 - PayClock Network Terminal Service
• 7351 - Auto Poll Service
• 2638 - PayClock Database Server