Brochure
Table Of Contents
- Packard_2018_Catalog_00_Cover
- Packard_2018_Catalog_01_motor
- Packard_2018_Catalog_02_Blowers
- Packard_2018_Catalog_03_OEM
- Packard_2018_Catalog_04_CoolingSolutions
- Packard_2018_Catalog_05_components
- Packard_2018_Catalog_06_controls
- Packard_2018_Catalog_06_Controls
- Packard_2018_Catalog_06_Controls-320
- Packard_2018_Catalog_06_Controls-321
- Packard_2018_Catalog_06_Controls-322
- Packard_2018_Catalog_06_Controls-323
- Packard_2018_Catalog_06_Controls
- Packard_2018_Catalog_06_Controls-328
- Packard_2018_Catalog_06_Controls-329
- Packard_2018_Catalog_06_Controls
- Packard_2018_Catalog_07_electrical
- Packard_2018_Catalog_07_Electrical
- Packard_2018_Catalog_07_Electrical-346
- Packard_2018_Catalog_07_Electrical-347
- Packard_2018_Catalog_07_Electrical-348
- Packard_2018_Catalog_07_Electrical-349
- Packard_2018_Catalog_07_Electrical
- Packard_2018_Catalog_07_Electrical-356
- Packard_2018_Catalog_07_Electrical-357
- Packard_2018_Catalog_07_Electrical
- Packard_2018_Catalog_08_AirHandling
- Packard_2018_Catalog_09_Accessories
- Packard_2018_Catalog_10_Index
- Packard_2018_Catalog_11_BackCover
packardonline.com
|
800.334.1769
258
COMPONENTS
|
Features
• Designed with contractor input
• Fingertip reset
• High visibility contrast scale
• Fail-safe bellows available
• Durable, rust proof plastic cover
• Universal mounting bracket
• Snap action switch
• Easy to maintain and access contacts with 24 FLA rating
• Large connector area
• Easy, direct replacements for most competitor controls
• Finger-tip test for contact operation
ADOPTED BY
ORIGINAL EQUIPMENT
MANUFACTURERS
Danfoss KPU Pressure Controls
Item ID
Pressure Type Reset
Contact
system
Range
(psig)
Dierential
(psig)
Max. Working
Pressure (psig)
Replaces
¼” M
are
36” capillary tube with
¼” are nut
Danfoss Pressure Controls
060-5231 060-5233 Low
KPU 1
Automatic SPDT 6”-108 10 to 60 250
O10-1483
060-5237 060-5235 Low KPU 2 Automatic SPST (open low) 6”-73 6 to 30 250
O10-1402
060-5239 060-5240 Low
KPU 2
Automatic SPDT 6”-73 6 to 30 250
060-5232 060-5234 Low KPU 1B Manual SPDT 28”-100 10 250
P70AB12
P70AB2
060-5241 060-5242 Fan cycling KPU 5 Automatic SPST (open low) 100-465 25 to 85 510
O10-2054
P70AA118
060-5243 060-5245 High KPU 6W
2
Automatic SPDT 100-600 58 to 145 675
O16-108
060-5244 060-5246 High KPU 6B
2
Manual SPDT 100-600 60 675
Item ID Low pressure side
Type
High pressure side Reset
Contact system
Max. Working
Pressure
(low / high
side) (psig)
Replaces
¼” M are
36” capillary tubes
w/ ¼” are nuts
Range
(psig)
Dierential
(psig)
Range
(psig)
Dierential
(psig)
Low
pressure side
High
pressure side
Danfoss Pressure Controls
060-5247 060-5248 6” to 108 10 to 60 KPU 15 100-465 60 Automatic Automatic
SPST dual
pressure
(LP/HP)
250 / 510
012-1549
060-5249 060-5250 6” to 108 10 to 60 KPU 15B 100-465 60 Automatic Manual
SPST dual
pressure
(LP/HP)
250 / 510
P170LB1
3
P70LB1
P70MA1
060-5253 060-5254 6” to 108 10 to 60 KPU 16B
2
100-600 60 Convertible
3
Convertible
3
SPDT
LP/HP signal
250 / 675
O12-4834
DANFOSS KPU CONTROLS
1
Competitor Part No. equipped with capillary tube for all but P170LB1 which has are connection.
2
KPU 6 and the high pressure side of KPU 16 are designed with fail-safe double bellows.
3
Convertible reset controls can be adjusted for either automatic or manual reset.
All controls are supplied with universal mounting brackets and mounting screws. Ambient temperature: -40˚ F to +122˚ F (175˚ F for maximum 2 hours).
KPU 1, 2, 6, 16 suitable for all HFC refrigerants, including R-410A.