Brochure
Table Of Contents
- Packard_2018_Catalog_00_Cover
- Packard_2018_Catalog_01_motor
- Packard_2018_Catalog_02_Blowers
- Packard_2018_Catalog_03_OEM
- Packard_2018_Catalog_04_CoolingSolutions
- Packard_2018_Catalog_05_components
- Packard_2018_Catalog_06_controls
- Packard_2018_Catalog_06_Controls
- Packard_2018_Catalog_06_Controls-320
- Packard_2018_Catalog_06_Controls-321
- Packard_2018_Catalog_06_Controls-322
- Packard_2018_Catalog_06_Controls-323
- Packard_2018_Catalog_06_Controls
- Packard_2018_Catalog_06_Controls-328
- Packard_2018_Catalog_06_Controls-329
- Packard_2018_Catalog_06_Controls
- Packard_2018_Catalog_07_electrical
- Packard_2018_Catalog_07_Electrical
- Packard_2018_Catalog_07_Electrical-346
- Packard_2018_Catalog_07_Electrical-347
- Packard_2018_Catalog_07_Electrical-348
- Packard_2018_Catalog_07_Electrical-349
- Packard_2018_Catalog_07_Electrical
- Packard_2018_Catalog_07_Electrical-356
- Packard_2018_Catalog_07_Electrical-357
- Packard_2018_Catalog_07_Electrical
- Packard_2018_Catalog_08_AirHandling
- Packard_2018_Catalog_09_Accessories
- Packard_2018_Catalog_10_Index
- Packard_2018_Catalog_11_BackCover
packardonline.com
|
800.334.1769
261
|
COMPONENTS
Features
• Designed with contractor input
• Fingertip reset
• High visibility contrast scale
• Fail-safe bellows available
• Durable, rust proof plastic cover
• Universal mounting bracket
• Snap action switch
• Easy to maintain and access contacts with 24 FLA rating
• Large connector area
• Easy, direct replacements for most competitor controls
• Finger-tip test for contact operation
ADOPTED BY
ORIGINAL EQUIPMENT
MANUFACTURERS
1
Bulb must be installed in colder position than thermostat
housing and capillary tube.
2
Temperature variations in excess of 70˚ F between sensing
bulb, housing, and capillary tube will inuence scale accuracy.
Danfoss KPU Temperature Controls
Item ID Type Bulb Type
Capillary
tube length (in.)
Reset Range (°F)
Dierential
Max. bulb
temp.
(°F)
Replaces
at lowest
temp. setting
at highest
temp. setting
Danfoss Temperature Controls
060L5201 KPU 61
Straight Capillary
Tube
1
80 Automatic -20 to 60 10 to 40 2.5 to 13 250
010-1416
O10-1010
O16-111
O10-1419
060L5206 KPU 62 Room sensor
1
Room sensor Automatic -20 to 60 10 to 40 2.5 to 13 250
A19BBC2
O10-1072
O60-1418
060L5215 KPU 68 Room sensor
1
Room sensor Automatic 25 to 95 8 to 45 3 to 13 250
O10-1802
O16-595
O10-301
O16-165
060L5208 KPU 73 Remote bulb
2
80 Automatic -15 to 60 6.5 to 32 5 to 50 175
A19ABA40
A19ABC24
O10-1408
O10-1409
060L5218 KPU 71 Remote bulb
2
80 Automatic 25 to 70 5.5 to 18 4 to 16 175
060L5223 KPU 77 Remote bulb
2
80 Automatic 60 to 140 6 to 18 6.3 to 18 265
O60-200
A19AAF-12C
A19AAB-4C
A19ABB-2C
A19ABB-7C
Item ID Type
Regulation
Range (°F)
Dierential
∆T (°F)
Bulb Type
Capillary Tube
Length (In.)
Max. Bulb
Temp. (°F)
Ambient Temp.
(°F)
Contact Type Reset Type Replaces
Danfoss
060L2150 KPU 19 -30 - 80 3.6 - 12.6 Remote 120 140 -31 - 158 SPDT Auto.
Penn A19ABC-24C
060L2151 KPU 19 -30 - 80 3.6 - 12.6 Remote 80 140 -31 - 158 SPST Auto.
Penn A19ABA-40C
060L2152 KPU 19 -30 - 80 3.6 - 12.6 Room Room Sensor 140 -31 - 140 SPDT Auto.
Penn A19BBC-2C
Thermostat Type KPU
Features
• Eliminates temperature uctuations.
• Reliable and robust SPST and SPDT contact system, copper capillary tubing
and bulb are stout to resist breakages.
Replaces Penn/Johnson
Controls and many others
thermostats.
Features
• Reliable, long life stainless steel bellows
• Sturdy metal cover and universal mounting hole patterns
• Integral 1/2” NPSM swivel connection allows direct attachment of
1/2” male pipe thread connector
• Simple manual trip, electrical test function eliminates need of tools
and test “jumper” wires
• Suitable for both alernating and direct current (AC and DC)
• Versions available with adjustable or xed dierential
DANFOSS KPU TEMPERATURE CONTROLS
NEW