CONTROLS
|
Blower and Furnace Controls
ICM Control Features and Applications Specications Replaces
Fan Blower Controls - Form, Fit and Functional OEM Replacement Parts
ICM275
Heavy duty heat relay
• Purges ducts of residual air
• Integral short cycle protection
• Voltage: 18-30 VAC
• Contact ratings:
High: 20 amps @ 240 VAC
Low: 10 amps @ 240 VAC
• Time delays:
Heat ON delay: 60 seconds
Heat OFF delay: 60-240 seconds
Cool OFF delay: 90 seconds
• Carrier: CES0110019,
HH84AA001, HH84AA003
HH84AA005, HH84AA009
HH84AA014, HH84AA015
HH84AA021
• Robertshaw: 695-101
ICM277
Microprocessor-based fan blower
• For circulating fan in heat pump, A/C and forced air
systems
• Voltage: 18-30 VAC
• Contact ratings:
N.O.: 20 amps
N.C.: 10 amps
• Time delays:
Blower ON: 7 seconds
Blower OFF: 65 seconds
• Goodman:
B1370735S
PCBFM131S
Furnace Controls
ICM280
Microprocessor-based fan blower
• Inducer fan outputs
• Hot surface ignitor output
• Flame sensor input
• Gas valve output
• Status LED for fault codes
Twinning compatible with another ICM280 board
Voltage: Line (98-132 VAC) @ 60 Hz
• Fan: 2 HP @ 240 VAC
• Inducer motor: 7 amps @ 250 VAC
• Gas valve: 1 amps @ 24 VAC
• Ignitor: 5 amps @ 120 VAC
• Goodman:
B1809906, B1809908,
B1809910, B1809913,
B1809913S
• UTEC: 1012-933D
Texas Instruments: 41F-5
• White-Rodgers:
50T35-730, 50T35-743
ICM281
Control gas valve, ignitor, blower motor, inducer,
humidier and air cleaner
• Microprocessor-based
• Designed for 100% gas shuto in case of ignition failure
• Model selection of 80+ and 90+ furnace operation
• Reverse polarity protection
• Secondary brownout voltage protection
• Heating and cooling fan functions in response to
standard thermostat
• Provides diagnostic LEDs to aid in troubleshooting
Twinning compatible with another ICM281 board
Voltage: Line (98-132 VAC) @
60 Hz
• Operating temperature:
-40°F to 176°F
-40°C to 75°C
• Ignitor: 5A @ 120 VAC
• Cool blower: 30A, 2HP, 240 VAC
• Heat: 5A, 1/2 HP, 240 VAC
• Inducer motor: 4A, FLA-8.0 LRA
@ 120 VAC
• Gas valve: 1.5A @ 30 VAC
• Carrier:
CES0110020
CES0110048
CES0110057-00
CES0110057-01
CES0110057-02
HH84A016
ICM282A
Control gas valve, ignitor, blower motor, inducer,
humidier & air cleaner
• Microprocessor-based
• Designed for 100% gas shuto in case of ignition failure
• Reverse polarity protection
• Secondary brownout voltage protection
• Heating and cooling fan functions in response to
standard thermostat
• Provides diagnostic LEDs to aid in troubleshooting
• Includes adapter harness (not shown)
Twinning compatible with another ICM282A board
Voltage: Line (98-132 VAC) @
60 Hz
• Operating temperature:
-40°F to 176°F
-40°C to 75°C
• Ignitor: 5A @ 120 VAC
• Cool blower: 30A, 2HP, 240 VAC
• Heat: 5A, 1/2 HP, 240 VAC
• Inducer motor: 4A, FLA-8.0 LRA
@ 120 VAC
• Gas valve: 1.5A @ 30 VAC
• Carrier:
HK42FZ004,
HK42FZ007
HK42FZ008
HK42FZ009
HK42FZ011
HK42FZ013
HK42FZ016
HK42FZ034
325878-751
ICM FURNACE CONTROLS