Brochure

packardonline.com
|
800.334.1769
292
CONTROLS
|
ICM Control Features and Applications Specications Replaces
Intermittent Ignition
ICM1503 • Safety Timing - 45 seconds • Carlin: 48245
• Honeywell: R8184G4009,
R8184G1138, R8184G1427,
R8184G4025
• Tempstar/Hell: 1147017
• White-Rodgers: 668-401
Duty Cyle Timers
ICM305 (minutes), ICM306 (seconds)
• Reliable duty cycle timer ideally suited for
defrost applications
• Suitable for process equipment or
applications requiring intermittent delays
• Switch-settable time delays
• Digital timing accuracy
• Reliable solid state output
• Epoxy-encapsulated for greater reliability
• On time starts at power up
Voltage: 18-240 VAC
1 amp / 10 amp inrush
Time delay: ICM305
Switch-settable from: 11,023 minutes
in 1 minute intervals
Time delay: ICM306
Switch-settable from: 11,023 seconds
in 1second intervals
• Dimensions: 2” x 3”
Defrost Controls - Form, Fit and Functional OEM Replacement Parts
ICM300
• Replacement for OEM Type 621
• Low cost, time and temperature defrost
• HOLD input tracks compressor run times
Time and temperature terminate
• 10-minute xed defrost time
• Pin-selectable intervals: 30/60/90 minutes
Test pins reduce test time by 256x
• Stable pin post construction
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Output: Relay, SPST
• N.O.: 1 amp
• Defrost time: 10-minute xed
• Interval times: Pin-Sel. 30/60/90
min.
• Amana: C64301-1, C64310-1
• Arcoaire: 32312-00, 3232140
• Artesian: 10321-00
• Coleman: 3030A374
• Essex: 621-1 to 621-11, 621-310
• Goodman: B12260-06
• Heil Quaker: HQ1052757
• Honeywell: ST74A1004, ST74A1020,
ST74A1038
• ICP: 1052757
• Intertherm: 6208800
• Lennox: 33G9501
• Rheem: 47-21776-01
• Robertshaw/Uni-Line: TD-10, DT2-
1000
• Snyder General: 1395-329
• Steveco: 90-621
• Therm-O-Disc: 26E-10
Weatherking (Addison): 840-4-5548
• White-Rodgers: 90-621
ICM301
• Low cost, time and temperature defrost
• Sensor input for defrost terminate
Time and temperature terminate
• 10-minute xed defrost time
• Pin-selectable intervals: 30/60/90 min.
Test pins reduce test time by 256x
• HOLD input accumulates actual
compressor run times
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Output:
Type: Relay, SPST N.O.: 1 amp
• Defrost time: 10-minute xed
• Interval times: Pin-Sel. 30/60/90
min.
• Goettl: 305007
• ICM: DFOSP24A2
• Rheem: 47-21776-06
ICM302
• Low cost, time and temperature defrost
Time and temperature terminate
• 10-minute xed defrost time
• Pin-selectable intervals: 30/60/90 min.
Test pins reduce test time by 256x
• Strip heat, reversing valve outputs
• High power output (1 HP fan at 240 VAC)
• Integral short cycle protection
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Output:
Type: Relay, SPST N.O.: 1 amp
• Anti-short cycle time: 5 minutes
• Defrost time: 10-minute xed
• Interval times: Pin-Sel. 30/60/90
min.
• ICM: DFORB-AB1004
• Nordyne:
621301A
621579B
621579C
917178
Ignition Controls, Duty Timers, and Defrost Controls