CONTROLS
ICM Control Features and Applications Specications Replaces
OEM Replacement Parts
ICM303
Time and temperature terminate
• Integral short cycle protection
• High/low pressure switch monitoring
• Strip heat, reversing valve outputs
• High power condensor relay output
Voltage: 18 to 30 VAC
• Frequency: 50/60 Hz
• Relay Output: 1 HP fan @ 240 VAC
• Strip Heat / Reversing Valve
• Outputs: 24 VAC, 2 amps
• Defrost time: Fixed 10 minutes
Interval Time Between Defrosts: Pin-
selectable 30/60/90 min
• Evcon 9218-374
York 03101251000
• 9218-3741
ICM307
• 3-minute, anti-short cycle protection
• Low cost, time and temperature defrost
Time and temperature terminate
• HOLD input tracks compressor run times
Test pins reduce test times by 256X
Voltage: 18 to 30 VAC
• Frequency: 50/60 Hz
• Output:
• Relay, SPST
• N.O.: 1 amp
• Anti-Short Cycle Time: 3 minutes
• Defrost time: xed 10 minutes
Interval time between defrosts: pin-
selectable 30/60/90 min
• Fast 1093410
• Lennox 86G16
• Ranco DT2
ICM315
• Solid state replacement for Ranco E-15
Reliable thermistor-type sensor is less
susceptible to breakage and easier to
mount
• Replaces faulty bulb-type sensors
Time and temperature terminate
Test pins reduce test times by 256X
• Stable pin post construction
Voltage: 24, 120, 240 VAC
• Frequency: 50/60 Hz
• Output:
• Relay, SPDT
• N.O.: 20 amps
• N.C.: 10 amps
• Defrost time: Fixed 10 minutes
Interval Time Between Defrosts: Pin-
selectable 30/45/90 min
• Ranco E-15
• Avion DFT100
ICM316
• Replacement for Trane 21C142827G01
• Low cost, time and temperature defrost
Time and temperature terminate
Test pins reduce test times by 256X
• High power output (1/2 HP fan @ 240 VAC)
Strip heat, reversing valve outputs (24 VAC,
1 amp)
Voltage: 24 VAC
• >Frequency: 50/60 Hz
Outdoor Fan Relay Output: 1/2 HP fan @
240 VAC
Strip heat, reversing valve outputs: 24 Vac,
1 amp
• Defrost time: Fixed 10 minutes
Interval Time Between Defrosts: Pin-
selectable 50/70/90 min
Trane 21C142827G01, CNT1152,
CNT1642
ICM317
• Anti-bang reversing valve feature
• Select 0 or 3 minute anti-short cycle time
Time and temperature terminate
Test pins reduce test time by 256X
• HOLD input tracks compressor run times
Voltage: 18-30 VAC
• Frequency: 50/60 Hz
• Output:
• Relay, SPST
• N.O.: 1 amp
• Defrost time: Fixed 10 minutes
Interval Time Between Defrosts: Pin-
selectable 50/70/90 min
Defrost Controls
ICM DEFROST CONTROLS