Brochure
Table Of Contents
- Packard_2018_Catalog_00_Cover
- Packard_2018_Catalog_01_motor
- Packard_2018_Catalog_02_Blowers
- Packard_2018_Catalog_03_OEM
- Packard_2018_Catalog_04_CoolingSolutions
- Packard_2018_Catalog_05_components
- Packard_2018_Catalog_06_controls
- Packard_2018_Catalog_06_Controls
- Packard_2018_Catalog_06_Controls-320
- Packard_2018_Catalog_06_Controls-321
- Packard_2018_Catalog_06_Controls-322
- Packard_2018_Catalog_06_Controls-323
- Packard_2018_Catalog_06_Controls
- Packard_2018_Catalog_06_Controls-328
- Packard_2018_Catalog_06_Controls-329
- Packard_2018_Catalog_06_Controls
- Packard_2018_Catalog_07_electrical
- Packard_2018_Catalog_07_Electrical
- Packard_2018_Catalog_07_Electrical-346
- Packard_2018_Catalog_07_Electrical-347
- Packard_2018_Catalog_07_Electrical-348
- Packard_2018_Catalog_07_Electrical-349
- Packard_2018_Catalog_07_Electrical
- Packard_2018_Catalog_07_Electrical-356
- Packard_2018_Catalog_07_Electrical-357
- Packard_2018_Catalog_07_Electrical
- Packard_2018_Catalog_08_AirHandling
- Packard_2018_Catalog_09_Accessories
- Packard_2018_Catalog_10_Index
- Packard_2018_Catalog_11_BackCover
packardonline.com
|
800.334.1769
299
|
CONTROLS
ICM Control Features and Applications Specications Replaces
OEM Replacement Parts
ICM303
• Time and temperature terminate
• Integral short cycle protection
• High/low pressure switch monitoring
• Strip heat, reversing valve outputs
• High power condensor relay output
• Voltage: 18 to 30 VAC
• Frequency: 50/60 Hz
• Relay Output: 1 HP fan @ 240 VAC
• Strip Heat / Reversing Valve
• Outputs: 24 VAC, 2 amps
• Defrost time: Fixed 10 minutes
• Interval Time Between Defrosts: Pin-
selectable 30/60/90 min
• Evcon 9218-374
• York 03101251000
• 9218-3741
ICM307
• 3-minute, anti-short cycle protection
• Low cost, time and temperature defrost
• Time and temperature terminate
• HOLD input tracks compressor run times
• Test pins reduce test times by 256X
• Voltage: 18 to 30 VAC
• Frequency: 50/60 Hz
• Output:
• Relay, SPST
• N.O.: 1 amp
• Anti-Short Cycle Time: 3 minutes
• Defrost time: xed 10 minutes
• Interval time between defrosts: pin-
selectable 30/60/90 min
• Fast 1093410
• Lennox 86G16
• Ranco DT2
ICM315
• Solid state replacement for Ranco E-15
• Reliable thermistor-type sensor is less
susceptible to breakage and easier to
mount
• Replaces faulty bulb-type sensors
• Time and temperature terminate
• Test pins reduce test times by 256X
• Stable pin post construction
• Voltage: 24, 120, 240 VAC
• Frequency: 50/60 Hz
• Output:
• Relay, SPDT
• N.O.: 20 amps
• N.C.: 10 amps
• Defrost time: Fixed 10 minutes
• Interval Time Between Defrosts: Pin-
selectable 30/45/90 min
• Ranco E-15
• Avion DFT100
ICM316
• Replacement for Trane 21C142827G01
• Low cost, time and temperature defrost
• Time and temperature terminate
• Test pins reduce test times by 256X
• High power output (1/2 HP fan @ 240 VAC)
• Strip heat, reversing valve outputs (24 VAC,
1 amp)
• Voltage: 24 VAC
• >Frequency: 50/60 Hz
• Outdoor Fan Relay Output: 1/2 HP fan @
240 VAC
• Strip heat, reversing valve outputs: 24 Vac,
1 amp
• Defrost time: Fixed 10 minutes
• Interval Time Between Defrosts: Pin-
selectable 50/70/90 min
• Trane 21C142827G01, CNT1152,
CNT1642
ICM317
• Anti-bang reversing valve feature
• Select 0 or 3 minute anti-short cycle time
• Time and temperature terminate
• Test pins reduce test time by 256X
• HOLD input tracks compressor run times
• Voltage: 18-30 VAC
• Frequency: 50/60 Hz
• Output:
• Relay, SPST
• N.O.: 1 amp
• Defrost time: Fixed 10 minutes
• Interval Time Between Defrosts: Pin-
selectable 50/70/90 min
—
Defrost Controls