Brochure

packardonline.com
|
800.334.1769
311
|
CONTROLS
Gas Ignition Controls
ICM Control Features and Applications Specications Replaces
OEM Replacement Parts
ICM2906
• Direct Spark Ignition (DSI) control board
• Cooling and heating fan outputs
• Microprocessor-based
Controls inducer motor, blower motor, air
cleaner (if equipped), spark ignitor and the
gas valve
Monitors timing, trial for ignition, system
switches, ame sensing and lockout
• Compatible with LP or natural gas
LED indication for status and fault codes to aid
in troubleshooting
Voltage: 18-30 VAC
Frequency: 60 Hz
Inducer blower type: Relay
Rating: 1/6 HP @125 VAC
Gas valves type: Relay
Rating: 1A @ 24 VAC
Heat blower type: Relay
Rating: 1/4 HP @125 VAC
Cool blower type: Relay
Rating: 1 HP @125 VAC
Operating Temp: -40°F to 165°F
Dimensions: 14.5” x 5”
Reznor: 195573
ICM2907
• Direct Spark Ignition (DSI) control board
• Microprocessor-based
Controls inducer motor, blower motor, air
cleaner (if equipped), spark ignitor and the
gas valve
Monitors timing, trial for ignition, system
switches, ame sensing and lockout
• Compatible with LP or natural gas
LED indication for status and fault codes to aid
in troubleshooting
Voltage: 18-30 VAC
Frequency: 60 Hz
Inducer blower type: Relay
Rating: 1/6 HP @125 VAC
Blower type: Relay
Rating: 1/4 HP @125 VAC
Gas valves type: Relay
Rating: 1A @ 24 VAC
Operating Temp: -40°F to 165°F
Dimensions: 14.5” x 5”
Reznor: 195265
ICM295
• Spark ignition control module
For use with intermittent pilot boilers,
furnaces and other heating appliances
• Microprocessor-based precision
• Continuous spark until pilot ame established
• Push-on, high tension quick connect terminals
Works with both Natural and LP gas systems
• Control voltage: line 24V (18-30 VAC), 50/60Hz
• Spark frequency: 15Hz for 90 seconds, 10Hz
thereafter
• Prepurge: 0 or 10 seconds (system dependent)
• Retry: Continuous
• Carrier LH33WZ510
ICM296
• Spark ignition control module
• F or use with intermittent pilot boilers,
furnaces and other heating appliances
• Microprocessor-based precision
• 100% safety lockout
Works with both Natural and LP gas systems
• Control voltage: line 24V (18-30 VAC), 50/60Hz
• Spark frequency: 60Hz
• Prepurge: None
• Lockout: 5-6 minutes
• Retry: None
• Relay contact rating: 1 amp @ 24 VAC
Trial for ignition: 90 seconds
• Flame failure response time: 0.8 seconds max.
• Carrier LH33WZ512
ICM GAS IGNITION CONTROLS