Freeze Protection
ICM Control Features and Applications Specications
Freeze Protection Modules
ICM308
• Low cost, xed, single setpoint temperature controls that provide
freeze protection
• Small compact package
• Epoxy encapsulated for moisture protection
Temperature sensor included
Temperature Cut-Out (OFF): 43°F
Temperature Cut-In (ON): 45°F
• Input:
Voltage: 18 to 30 VAC
• Frequency: 50 to 60 Hz
• Output:
• Solid state (triac)
• 1.5 amps at 30 VAC
ICM309
• Low cost, xed, single setpoint temperature controls that provide
freeze protection
• Small compact package
• Epoxy encapsulated for moisture protection
Temperature sensor included
Temperature Cut-Out (OFF): 28°F
Temperature Cut-In (ON): 55°F
• Input:
Voltage: 18 to 30 VAC
• Frequency: 50 to 60 Hz
• Output:
• Solid state (triac)
• 1.5 amps at 30 VAC
ICM310
• Low cost, xed, single setpoint temperature controls that provide
freeze protection
• Small compact package
• Epoxy encapsulated for moisture protection
Temperature sensor included
Temperature Cut-Out (OFF): 44°F
Temperature Cut-In (ON): 48°F
• Input:
Voltage: 18 to 30 VAC
• Frequency: 50 to 60 Hz
• Output:
• Solid state (triac)
• 1.5 amps at 30 VAC
Defrost Control
ICM222
• Replacement for Goettl 305023 controls
• voltage: 18-30 VAC
• Frequency: 50/60 Hz
• CC
Type: Solid state (Triac)
• Rating: 1 amp @ 30 VAC
• Fault
Type: Relay (SPDT) N.O.
• Rating: 1 amp @ 30 VAC
Anti-short cycle time: 5-minutes xed ±20%
(5-second test mode)
• Dimensions: 3.5” x 3.25” x 1”
Temp Stat
SC055
These low cost, single setpoint thermostate are intended for use as
temporary devices to provide heating or cooling to allow drywall to
dry during construction. They can also be used as a low ambient
cuto switch for a condensor fan motor.
• Low cost dryout thermostats
• Can be used for low ambient cuto switch
• Simple two-wire installation
• Six xed setpoint: 55°F
• Input: 18-30 VAC
• Output: 2 amp maximum
• Switch Opens: below 55°F
• Switch Closes: above 55°F
• Accuracy: (+/- 9°F)
ICM CONTROLS
Features
Packard transformers replace models with equal or lower VA rating
Foot mount
Class II transformers
Item ID Primary Voltage VA Rating Secondary Rating Mounting Option Connection Replaces
Packard
PF12416 120 10VA 16 Foot Wire Lead / Term
UET 10A
Item ID Primary Voltage VA Rating Secondary Rating Mounting Option Connection Replaces
Packard
PF22440 208/240 40VA 24 Foot Wire Lead
Jard 4021F
Item ID Primary Voltage VA Rating Secondary Rating Mounting Option Connection Replaces
Packard
PF12440 120 40VA 24 Foot Wire Lead
Jard 4011F
Item ID Primary Voltage VA Rating Secondary Rating Mounting Option Connection Replaces
Packard
PF40224 208/240 40VA 24 Foot Terminals Goodman 013M00138S
Item ID Primary Voltage VA Rating Secondary Rating Mounting Option Connection Replaces
Packard
PF24200 120 20VA 24 Foot Wire Lead / Term Williams Furnace 24200
Item ID Primary Voltage VA Rating Secondary Rating Mounting Option Connection Replaces
Packard
PF42420 120/208/240 20VA 24 Foot Wire Lead
Jard 2031F
UET 114
Class II Foot Mount Transformers
Item ID Primary Voltage VA Rating Secondary Rating Mounting Option Connection Replaces
Packard
PF113 120 40VA 24 Foot Wire Lead/Term
90-113 Fan Center Transformer
Item ID Primary Voltage VA Rating Secondary Rating Mounting Option Connection Replaces
Packard
PF40115 120 40VA 24 Bracket 1/4” QC Term.
Goodman 013M001405
Item ID Primary Voltage VA Rating Secondary Rating Mounting Option Connection Replaces
Packard
PF137 208/240 40VA 24 Foot Wire Lead
First Company E137
Item ID Primary Voltage VA Rating Secondary Rating Mounting Option Connection Replaces
Packard
PF12406 120 40VA 24 Foot Wire Lead
46-24124-06
Item ID Primary Voltage Secondary Rating Output Option Mounting Option Connection Replaces
Packard
PF90501 208/240 40VA 24 Foot 1/4” QC Term.
46-101905-01
TRANSFORMERS