Brochure

packardonline.com
|
800.334.1769
327
|
CONTROLS
Features
Temperature range: 40 °F to 130°F
Class B insulation
Continuous duty
UL recognized
Item ID
Continuous Pick-Up Drop Out Coil Data Class
ReplacesCoil Voltage Min. Max. Max. DC Res MA Nom. VA Inrush VA Insulation
Packard
PR9026 395 180 195 100 7147 12.7 5 10 B
90-26, 19008
PR9063 170 140 153 65 1399 29 5 10 B
90-63, 19002
PR9064 395 245 275 140 7147 12.7 5 10 B
90-64, 19003
PR9065 332 171 184 90 5180 15 5 10 B
90-65, 19004
PR9066 395 208 239 130 7147 12.7 5 10 B
90-66, 19005
PR9067 420 300 328 121 10000 12 5 10 B
90-67, 19006
PR9068 495 323 352 135 11950 10 5 10 B
90-68, 19007
PR9071 420 223 252 150 10000 12 5 10 B
90-71, 19010
PR9169 332 180 193 105 5600 12 5 10 B
19008
Universal Motor Starting Relay
Potential Relays
Features and Applications Specications Replaces
ICM Controls
UMSR-50
• Replacement for all standard potential
relays
• Patented dierential voltage sensing
• No user-adjustments required
• Non-positional mounting conguration
• 50A switching capabilities
• Universal mounting bracket for easy
installation
• .250” quick connect termination
• Safety timer
General:
• Input:
• Voltage Rating: 110-270 VAC,
Single Phase
• Maximum Voltage Contact
Rating: 502 VAC (absolute)
• Motor power rating: Up to 10 HP
• Operating Position: Non-positional
• Safety Time Out: Approximately
1-second per 100 microfarads
• Consumption: 5VA max.
• Insulation: Class B (130°C);
Conforms to IEC 1000- standards (6kV
impulse / 6kV contact)
• Life Expectancy (min. operations):
• Mechanical: 1 x 106
• Electrical: 1x106 at 16A 400 VAC
5x105 at 35A 400 VAC (break only)
5x105 at 50A 400 VAC (break only)
Contacts:
• Contact rating:
50A (break only),
400 VAC cos Ø = 0.7 to 0.8
• All standard potential relays
• Supco: APR5, SUPR
RELAYS