Brochure

packardonline.com
|
800.334.1769
58
MOTORS
|
Permanent Split Capacitor Condenser Fan Motors
Features
Permanent split capacitor
Single speed
Reversible rotation
Totally enclosed
Automatic overload
48 Frame
60 Hertz
Single phase
Rheem Mounting
Item ID H.P. Volts RPM Amps
Shaft Dim.
(In.)
Length Less
Shaft (In.) Bearings Capacitor Required Replaces Notes
Century
FSE1016SV1 1/6 208-230 1075 0.90 1/2 x 6 1/2 4 Sleeve 5MFD/370V
189, 422
FSE1026SV1 1/4 208-230 1075 2.00 1/2 x 6 1/2 4 3/8 Sleeve 5MFD/370V
189, 422
FE1026SC 1/4 208-230 1075 1.30 1/2 x 6 4 5/8 Ball 5MFD/370V
189, 246
FSE1036SV1 1/3 208-230 1075 1.80 1/2 x 6 1/2 4 7/8 Sleeve 7.5MFD/370V
189, 422
FE1036SC 1/3 208-230 1075 1.80 1/2 x 6 5 1/4 Ball 7.5MFD/370V
189
FSE1056SV1 1/2 208-230 1075 2.80 1/2 x 6 1/2 5 3/8 Sleeve 10MFD/370V
189, 422
FE1056SC 1/2 208-230 1075 2.80 1/2 x 6 5 5/8 Ball 10MFD/370V
189
FSE1076SV1 3/4 208-230 1075 4.20 1/2 x 6 1/2 5 5/8 Sleeve 15MFD/370V
189, 422
Fasco
D799 1/8 208-230 825 0.90 1/2 x 6 4 Sleeve 5MFD/370V
126, 138, 208, 517
D919 1/8 208-230 1075 0.90 1/2 x 6 1/2 3 3/4 Sleeve 5MFD/370V
126, 135, 208, 517
D917 1/6 208-230 1075 1.00 1/2 x 6 1/2 3 3/4 Sleeve 5MFD/370V
126, 135, 208, 517
D794 1/5 208-230 825 1.30 1/2 x 6 4 1/3 Sleeve 5MFD/370V
126, 138, 208, 517
D906 1/5 208-230 1075 1.20 1/2 x 6 1/2 4 Sleeve 5MFD/370V
126, 135, 208, 517
D934 1/4 208-230 825 1.90 1/2 x 6 4 1/3 Sleeve 5MFD/370V
126, 138, 208, 517
D909 1/4 208-230 1075 1.80 1/2 x 6 1/2 4 Sleeve 5MFD/370V
126, 135, 208, 517
D7909 1/4 208-230 1075 1.80 1/2 x 6 1/2 4 Ball 5MFD/370V
126, 135, 208, 517
D936 1/3 208-230 825 2.00 1/2 x 6 5 Sleeve 7.5MFD/370V
138, 208, 517
D908 1/3 208-230 1075 2.40 1/2 x 6 1/2 4 1/2 Sleeve 7.5MFD/370V
126, 135, 208, 517
D7908 1/3 208-230 1075 2.60 1/2 x 6 1/2 4 1/2 Ball 7.5MFD/370V
126, 135, 208, 517
D7907 1/2 208-230 1075 3.70 1/2 x 6 1/2 5 Ball 10MFD/370V
135, 208, 517
D913 1/4 460 1075 1.10 1/2 x 6 3/8 4 Ball 5MFD/370V
135, 208, 517
D915 3/4-1/2 460 1075 2.5-1.6 5/8 x 4 1/2 5 1/3 Ball 15MFD/370V
145, 146, 208, 517
Notes:
126. 4 drilled and tapped holes in shell for Rheem applications
135. All angle mount bearings
138. All angle mount bearings. Use rain shield when necessary
145. Special wiring conguration. Cannot be used with SPDT
switching.
146. Keyed Shaft
189. Reversing plug
208. 60ºC ambient
246. No hubs on either end
422. 1/2” hub on shaft end frame with slinger. Grommet on lead
exits.
517. Electrically reversible
TFM55
!
Torsion Flex Brackets.
See page 411 for
complete line.
CONDENSER FAN