Brochure

packardonline.com
|
800.334.1769
77
|
MOTORS
Item ID HP RPM Volts Frame Model No.
Cap.
Required
F.L.
Amps
Weight
(lbs.)
Frame
Length (in.)
Shaft Dim.
(in.)
Length Less
Shaft (in.)
Marathon
X477 1/6 1625 115 48Y 48A17O128 5MFD / 370V 2.6 9 4 1/2 x 4 5
X475 1/6 1625 230 48Y 48A17O123 5MFD / 370V 1.3 9 4 1/2 x 4 5
X473 1/6 1075 115 48Y 48A11O1046 5MFD / 370V 2.9 9 4 1/2 x 4 5
X471 1/6 1075 230 48Y 48A11O1044 5MFD / 370V 1.3 10 4 1/2 x 4 5
X476 1/4 1625 230 48Y 48A17O124 5MFD / 370V 1.8 10 4 1/4 1/2 x 4 5.25
X472 1/4 1075 115 48Y 48A11O1045 5MFD / 370V 4.0 11 4 1/4 1/2 x 4 5.25
X474 1/4 1075 230 48Y 48A11O1047 5MFD / 370V 2.0 11 4 1/4 1/2 x 4 5.25
Features
Open frame and brackets
Heavy gauge steel frame and base
Shaft with at side
Reversible rotation
70°C ambient
37” Leads
Thermal overload protection
1/4” terminals on the capacitor leads
2 1/4” resilient rings, includes 2 1/2” expanders
Capacitor not included
Direct Drive, PSC, Open Air Over, Resilient Ring
Application
Single speed PSC motors designed to replace PSC and Shaded pole motors, used in direct drive furnace, air conditioners, and others blowers.
Item ID HP RPM Volts Frame Model No.
Cap.
Required
F.L.
Amps
Weight
(lbs.)
Frame
Length (in.)
Shaft Dim.
(in.)
Length Less
Shaft (in.) Notes
Marathon
X038 1/2 1075/2 460 48Y 48A11O1874 10MFD / 370V 1.6 17 5 1/4 1/2 X 6 6.19
51
X039 3/4 1075/2 460 48Y 48A11O1875 15MFD / 370V 2.1 19 5 1/2 1/2 X 6 6.44
51
Direct Drive, PSC, Open Air Over, Extended Thru-Bolt, 460 Volt
Application
Residential and commercial furnaces, air conditioners, exhaust fans, and other air handling equipment installed in clean and dry environments.
Features
Enclosed frame and open end brackets
Multi-speed capability
Grommeted lead exit
Weather resistant reversing plug
Automatic reset thermal protector
7/8” extended thru-bolts on shaft end
Ball bearings
UL recognized and CSA certied
Capacitor not included
Notes:
51. Does not include resilient rings
For additional product
information visit
packardonline.com.
MARATHON DIRECT DRIVE BLOWER