Installation Guide

TLT240SC Two-post User’
s Manual
12
10.2.2 Base plate layout
TLT240SC symmetric installation is shown in Fig. 9
With total width (A) as the basis, draw two parallel
lines (#1 and #2) on the concrete slab, with the error
within 3mm.
Determine the power side column location on any
chalk line, and mark the total width (B) of the base
plate. Mark the points 3 and 4.
Starting from point 3, draw one diagonal line (C),
forming a triangle. In this way, the vertical lines can
determine the location of the two columns.
Fig.9
TLT240SC asymmetric installation is shown in Fig.10
With total width (A) as the basis, draw two parallel
lines (#1 and #2) on the concrete slab, with the error
within 3mm.
Determine a point B at any point on chalk line #1,
based on point B, move down 131mm, then move
right 228mm to get point C. Based on point B, draw
#1’s vertical line M with a length of A to get point
D .Based on point C, draw line M’s parallel line N with
a length of L to get point E. With four points B,C,D,E,
each post’s position can be decided.
TLT240SC:3563mm(140.28in)
TLT240SC:3107mm(122.32in)
228mm(8.98in)
1
3
1
m
m
(
5
.
1
6
i
n
)
228mm(8.98in)
1
2
B
C
E
D
M
N
L