Installation Guide

TLT240SC Two-post User’
s Manual
13
Note:
All the dimensions are based on the external
border of the base plate.
Ensure the overall error is controlled within 6mm.
In this way, the difficulties in the final assembly,
or early wear or non-alignment of the chain can
be eliminated. The marking and layout is very
important. If it is inaccurate, there will be
problems during the final assembly and
operation.
10.2.3
Install the power side column
For clear-floor two post lift, first install extension
column with column, then use lifting equipment to
place power side column upper right to the location.
Align the base plate of column with the chalk line
layout. Guided by holes on the base plate of the
column, used 5 concrete anchor bolts to fix it onto the
ground. Drill and install anchor bolts at one time, during
the drilling process, ensure no movement of the
column. (Fig.11).
M19×140 anchor bolts
1
0
8
m
m
(
4
.
2
5
i
n
)
10 sets
φ19mm
(φ0.75in)
Drill
Clean
1
0
8
m
m
(
4
.
2
5
i
n
)
Fasten
Expand
Concrete intensity should be above 3000PSI(2.1Kg/mm )
column
2
column
4000mm(157.5in)
Width 1800mm(70.9in)
Fig.11
Note
Use sharp
Φ
ΦΦ
Φ
19mm concrete drill-bit to drill the
holes so as not to drill the hole too large. Use
proper pneumatic tool to remove the dust from
the hole. The depth of the hole is the same as that
of the anchor bolt. Insert the anchor bolt and
make the washers lean against the base of the
column.
Only use torque wrench instead of impact tools to
fasten anchor bolts.
Insert proper steel shim under the base seat of
column to plumb the column.
Note: The thickness of shims shouldn’t exceed
5mm.
To get the correct and safety installation, please follow
the following installation steps.
Wear the safety goggles
Use hard alloy drill-bit.
Don’t use the drill-bit with wearing exceeding the
tolerance.
The drill and concrete surface should be kept
perpendicular.
Let the drill work itself. Don’t apply the extra force,
and don’t ream the hole or allow the drill to wobble.
The drilling depth of hole is based on the length of