Product Manual

23
INSTALLING THE PADDED SAFETY BAR AND SHUTOFF SWITCH
Install the safety shut-off electrical switch to the bracket on the underside of the overhead
beam adjacent to the power unit column. Use the provided shoulder bolt and cotter pin to
attach to the bracket and then route the electrical cord up into the overhead beam via the
small hole next to the bracket. When this is done the shut-off switch will be in a vertical
position. When the shut-off bar is installed shut off bar will protrude into the open end of the
safety switch as shown in the photo below.
After inserting the rounded end of the shut off bar into the electrical switch (as shown
above) connect the flatted end of the padded shut off bar to the underside of the
overhead beam adjacent to the slave side column using the provided should bolt and
nut. See photo below for reference.
Note: The Electrical Shutoff Switch cord will be connected when the power unit is
installed.
Power Unit Column
Shoulder Bolt
Slave Side Column
Electrical Safety
Shut
-
Off Switch
Padded Shut
-
Off Bar