After bleeding the hydraulic system and checking for leaks, install all of the
metal hose covers. In the parts box you will find small threaded bolts with
the top of the bolt drilled and taped. Install these bolts into the predrill holes
on the side of each column. On the power unit side at the hydraulic “T” fitting
a special hose cover with a cutout to allow for the “T” connectors shall be
used. Cover each section of the hose and then use the marching bolts to
attach the hose covers to the special predrilled bolts. Reference the photo
below that shows the “T” fitting and hose covers.
Hose cover studs
and screws
Hose cover cutout
Hose from the Power