Product Manual

47
and magnitude of energy that the lift utilizes and shall understand the
associated hazards.
ELECTRICAL:
Located at the user control panel, press the “E-STOP”
button to disconnect the raise and lower functions.
ELECTRICAL ENERGY IS STILL PRESENT AT THE LIFTS
ELECTRICAL PANEL WHEN THE EMERGENCY STOP
BUTTON IS PRESSED. ELECTRICAL ENERGY MUST BE
TURNED OFF AND ISOLATED AT THE DISCONNECT
PANEL PRIOR TO PERFORMING SERVICE OR
MAINTANANCE ON THE LIFT.
ISOLATION AND VERIFICAITON PROCEDURES:
Table 1: ISOLATION AND VERIFICATION PROCEDURES:
ENERGY TYPE
AND SOURCE
LOCKOUT
LOCATION
(TO BE
COMPLETED
BY END
USER)
PROCEDURE FOR LOCING OUT
AND OR RELEASING ENERGIES
VERIFY PROCEDURES
STORED
ENERGY
AND
HYDRAULIC
PRESSURE
3000-5000
PSI
LOWER THE LIFT TO ITS
LOWEST REST POSTION. IF THE
LIFT MUST BE SERVICED OR
MAINTAINED IN THE RAISED
POSITION, ENSURE THAT THE
LIFT IS PLACED ON THE
MECHANICAL LOCKS.
FOR SCISSOR LIFTS,
ADDITIONAL SUPPORT WITH
SUPPLEMENTARY JACK
STANDS, BLOCK AT THE
SLIDERS AND A COME ALONG
SECURED BETWEEN THE
SCISSORS.
FOR 4-POST LIFTS, ADDITIONAL
SUPPORT WITH
SUPPLEMENTARY JACK
STANDS.
VERIFY THAT THE LIFT IS (IF
APPLICABLE):
CONTACTING THE
MECHANICAL LOCKS,
RESTING ON THE
SUPPLEMENTARY JACK
STANDS,
BLOCKS ARE SECURLY PLACED
COME ALONG IS SECURED
BETWEEN THE SCISSORS.