Instructions / Assembly

16
16. Screw the regulator to the hose.
Install the gas cylinder
Open the door and put the gas cylinder onto the base,
then secure it with gas cylinder secure belt. And then
screw the regulator to the gas cylinder contector.
WARNING: Use a standard 20 lb. propane cylinder
only.
Use this heater only with a propane vapor
withdrawal supply system. See chapter 5 of the
standard for storage and handling of liquefied
petroleum gas, ANS/NFPA 58. Your local library or
fire department should have this book.
A minimum supply pressure of 0.4 P.S.I. is required
for the purpose of input adjustment for propane
gas. Storage of an appliance indoors is permissible
only if the cylinder is disconnected and removed
from the appliance. A cylinder must be stored
outdoors in a well-ventilated area out of the reach
of children. A disconnected cylinder must have dust
caps tightly installed and must not be stored in a
building, garage or any other enclosed area. The
minimum permissible gas supply pressure of 10
W.C. is required for purpose of input adjustment. A
minimum of 17,000 BTUs per hour is the required
input rating for a heater with a rating less than full.
The pressure regulator and hose assembly
supplied with the appliance must be used.
The installation must conform with local codes,
or in the absence of local codes,with national fuel
gas code, ANS Z223.1/NFPA54, natural gas and
propane Installation Code, CSA B149.1, or propane
storage and handling code, B149.2.
E
D
-10-