Use and Care Manual

www.LaViewUSA.com30
5. After reboot of device, enter the HDD
Information interface.
Menu > HDD> General
6. Select HDD from the list and click the
icon to enter the Local HDD Settings
interface, as shown in Figure 10. 11.
Local HDD Settings Interface
7. Select the Group number for the current
HDD.
Note: The default group No. for each HDD is 1.
8. Click the OK button to conrm settings.

9. In the pop-up message box, click the Ye s
button to conrm the settings.
Setting HDD Property
Purpose:
The HDD property can be set to redundancy, read-
only or read/write (R/W). Before setting the HDD
property, please set the storage mode to Group
(refer to steps 1-4 of Chapter Setting HDD Groups
).
A HDD can be set to read-only to prevent
important recorded les from being overwritten
when the HDD becomes full in overwrite recording
mode.
When the HDD property is set to redundancy, the
video can be recorded both onto the redundancy
HDD and the R/W HDD simultaneously so as to
ensure that reliability of video data is highly secured
and realiable.
Steps:
1. Enter the HDD Information interface.
Menu > HDD> General
2. Select HDD from the list and click the
icon to enter the Local HDD Settings
interface, as shown in Figure 10. 13.
Set HDD Property
3. Set the HDD property to R/W, Read-only
or Redundancy.
4. Click the OK button to save settings and
exit the interface.
5. In the HDD Information menu, the HDD
property will be displayed in the list.
Note: At least 2 hard disks must be installed on
your NVR (and one must be set to R/W property) if
you want to set a HDD to Redundancy.