User Manual

Installation Instructions for
700MOPCEN_
1
4” Single or Dual Flexible Power Feed Canopy
980MRLA4PFC
1.2
REMOTECNPY-_
Loosen the set screws on each strain(Do Not Remove)
relief. Dual Feed will have two set screws on each strain
relief.
Cut the end power feed wires to the desired length.
With a sharp knife cut 1" from the end of the wire web
and separate the wires 8" from each other.
Push the power feed wires through the strain reliefs
leaving at least 6” of cord in the back of the canopy for
wire connections.
Re-tighten the set screws.
2
3
4
1
1A
2A
Strip 1/2" off the wire ends and connect them to the
electrical box low voltage wires with the provided wire
nuts.
If installing a Dual Power Feed Canopy, repeat steps 1
through 5 for the second power feed cord using the
(HOT and COM) wire labeling to match wire labeling
from the transformer.
6
SET SCREW
1B
6
1
6
2A
STRAIN RELIEF
Note: If mounting the canopy onto an octagonal
electrical box, first mount the provided universal
mounting plate before proceeding to this step.
7
5
Install the Canopy
NOTE: Low voltage wires must be present in
electrical box before proceeding with these steps.
Refer to the instructions provided with the
remote transformer.
NOTE: The Power Feed wires may be connected
directly to the transformer, Refer to the
instructions provided with the remote
transformer for connection details.
GP I :ENERAL RODUCT NFORMATION
This product is suitable for indoor dry locations only.
This product must be used with LBL Lighting 2-Circuit MonoRail
system only.
SPECIAL INSTALLATION