Manual

CONDUIT
LOW VOLTAGE
WIRES
3
Install a conduit from the transformer to the electrical
box.
For the best performance, use the "Low Voltage Wire
Size Table" below to select the wire size.
Install the low voltage wires from the transformer to the
electrical power feed box.
Connect one red transformer wire to each low voltage
wire with a wire nut.
TRANSFORMER
WATTAGE
WIRE SIZE
FOR 5 FT
WIRE SIZE
FOR 6-15 FT
WIRE SIZE
FOR 16-20 FT
WIRE SIZE
FOR 21-40 FT
WIRE SIZE
FOR 40-60 FT
WIRE SIZE
FOR 61-90 FT
LOW VOLTAGE WIRE SIZE TABLE
150 WATT #8 GA #6 GA #4 GA #2 GA #1 GA#12 GA
10
11
8
9
NOTE: Other wire sizes that comply with electrical
code can be used, but may result in an increased
voltage drop and reduced lamp intensity.
NOTE: The THHN wire sizes are for 3% or less drop
in voltage based on 150 watt loads. Lengths are the
distance from the transformer to the system power
feed connector.
1A1C
10
11
8
11
8
10