Mounting procedure TCU Ref : C3131320010
Version : A1
Cable management in the TCU neighborhood.
Incorrect wiring will prevent the system from operating properly.
TCU has to be connected to +12V or +24V through 5A fuse protection.
TCU must be connected on Ignition (IGN).
When TCU and ECU or EBS are connected to a same CAN network, they must share the
same ground.
LDL Technology can provide the wiring harness (see table below) :
Nota : This cable has a minimum curvature radius about 80mm.
Reference Description
11 231 0000 Harness CAN (#1-Can)
11 232 0000 Harness (#1)
15 018 0000 Cable TCU CAN 1,2m - Wabco
15 017 0000 Cable TCU CAN 1,2m - EB+ gen3 - Haldex
15 016 0000 Cable TCU CAN Y 1,2m - EB+ gen2 - Haldex
15 015 0000 Cable TCU CAN 1,2m - EB+ gen2 - Haldex
15 014 0000 Cable TCU CAN 1,2m Deutsh 4 contacts 0462-201-16141 - Knorr
15 024 0000 Cable TCU CAN 1,2m – WABCO GIO5
C3131320010-A1-TCU_Mounting_Specification.odt LDL Technology SAS – Toulouse – France 10/ 16