Mounting procedure TCU Ref : C3131320010
Version : A1
LDL TCU bracket combinations
To link a base support to an extension support , 2 bolts are needed, type M6, length 16mm,
with 2 M6 washers (1 standard type and 1 Belleville type).
6. TCU POWER SUPPLY CONNECTION
Cable must be fastened between 100mm and 200 mm away from its TCU starting point.
Verify that no tension stress is applied onto the harness between TCU connector and the
fixation point onto the vehicle chassis AND after connection of the harness connector onto the
TCU connector.
From the TCU connector base to the fixation point away TCU (100 to 200 mm), the harness
cable must be in line as much as possible with the TCU connector terminal axis and not curved
over 30° see picture on next page below.
The connector must be secured after clipping (move the red CPA (Connector Position
Assurance) onto the harness connector toward the TCU connector)
C3131320010-A1-TCU_Mounting_Specification.odt LDL Technology SAS – Toulouse – France 9/ 16