Mounting procedure
TCU 1.2
Ref : C3140690010
Version : A1
Pin number Mnemonic Function
5 RS_RX2 Serial reception 2
6 RS_TX2 Serial transmission 2
7 FG_GND Fuel gauge ground
8 FG_PWR Fuel gauge power supply
4. TCU1.2 MOUNTING INTERFACE
The TCU 1.2 is mounted on a plane surface fixed on the vehicle frame. The TCU 1.2 has 3
mounting points equipped with silent blocks. The TCU 1.2 must be fixed on a support (available
on demand). This support (“TCU 1.2 interface”, also called “Bracket base”) is defined in the
appendix.
5. TCU 1.2 MOUNTING RECOMMENDATIONS
Screws (not provided by LDL) must be tightened @ 4,5 Nm +/-0,5 Nm. It's recommended to use
an elastic washer (Belleville type) between screw head and silent block with spacer. Stainless
steel is recommended.
M6 bolts are recommended, the screw for a fixation on a base plate fixation in thickness 1,5mm
must have a length equal or higher than 20mm.
NOTA BENE : The usage of a different bracket; without LDL written
approval; would void the warranty of the TCU 1.2.
C3140690010-A1-TCU12_Mounting_Specification.odt LDL Technology SAS – Toulouse – France 6/ 13