User manual

Layout-Light-Control Light-DEC Manual
- 15 -
Select the day phases with the keys ABOVE or BELOW for your relevant
adjustments.
With the key RIGHT you will go to the adjustments
of the selected day phases:
With the keys LEFT and RIGHT you can select as usual the adjustments between
}hour{, }minute{ and }factor{. Values between the curly brackets (} {) can be edited
with the keys ABOVE or BELOW.
After completing the day phases you have to
depress the key LEFT several times until after a
warm start the operation display will be indicated:
8. Setup of switch groups and switch times
Via switch groups with defined switch times will be the output functions of the day
phases with reference to the adjusted switch times switched on and off. If required
will be a suitable switch-group assigned to an output-function. Several output-
functions can be assigned to each switch-group. If you have a switch-group with
e.g. a timewise on- and off-activated welding light you can arrange the working
time and exclusively the time breaks. The welding light will be in this case active
only during the working hours of the day phase.
At the technical manual you will find within the tableSwitch groups with example:
Working hours at the factory” the switch group 1 established.
Here are the working hours at the production of a factory determined. Via this
switch-group can be the output-function welding light activated and deactivated
during the day phase.
At he switch-group 1 are within the first switch-time the working hours from 7:00
(a.m.) till 8:40 (a.m.) defined. Then comes the breakfast time.
At the second switch-time is the working time defined from 9:00 (a.m.) till 12:00
(a.m.) lunchtime.
The working time from end of lunch time to end of work 12:40 (12:40p.m.) till 16:00
(4:00 p.m.) will be defined within the third switch-time.
At the table are e.g. the switch-times of further switch-groups around the factory
registered. With this switch groups can be e.g. the illumination at different rooms of
the factory activated and deactivated during the day phase.
There are maximal 24 switch groups available for the adjustments of 5 switch times
with on- and off-switch times each for the day phase.
The Switching group table for own adjustments” at the Technical Manual can be
used for the documentation of times of your switch-groups. Additionally you can
download this table from our Web-Site at a DIN-A4 format.
Daybreak
}06{ : 30 F: 300
Light-DEC VX.X
23:30:00 A 300