User manual

Layout-Light-Control Light-DEC Manual
- 20 -
Depress the key LEFT for deleting the preinstalled
initial functions. Now it will be indicated that the
clamps 1 to 8 will be vacant.
With the key RIGHT you can change to the
possibility to set-up a new light function as initial
function at this clamp section. As a first
possible light function will be always the Railway
crossing initiated:
With the key BELOW can be the available light-functions indicated at the
sequence as they are listed at the Technical Manual under the headline “Description
of the available light functions.
With the key ABOVE will be the reversal sequence indicated.
If the indicated light-function need more clamps as actual vacant there will come
an Info at the lower line with changing to the name of the light-function the letters
Not possible”.
Select with the keys ABOVE or BELOW the light-
function ON/OFF. With this light-function will be
the output 1 initiated as switch output e.g. for a
lightsource or a motor.
11.1. Output function: properties always active
Depress now the key RIGHT for selecting the
output function for a property. There are 4
properties available. The display will indicate the
first property:
Always active signifies das the output function will be activated as soon as the
day phase function of the Light-control Light-DEC will be started. The output
function will be deactivated if the day phase function will stop.
11.2. Output function: properties switch group
If you want to activate or deactivate timely an output-function during the day phase
via a Switchgroup you have to depress the key ABOVE or BELOW until
>Switchgroup< will be indicated at the display. Now depress the key RIGHT.
If there was no Switchgroup determined for the
output-function before, this will be indicated at
the display with ““.
If there was already a switch-group determined, this will be indicated at the
display.
Select with the keys ABOVE or BELOW the
suitable Switchgroup. There will be only
Switchgroups for selection indicated for those
switchtimes are released.
During the day phase will be the output-function activated with relation to the
switch times which are selected and released for the relevant Switchgroup as
described within chapter 8 of this manual.
1 = LDM-KL:01-08
**** FREE ****
1 = LDM-KL:01-02
>Railway cross<
1 = LDM-KL:01
>ON / OFF<
Property
>Always active<
Property
Switchgroup:>
--
<
Property
Switchgroup:>02<