User manual

Littfinski DatenTechnik (LDT)
Operating Instr
uction
s88-N
16-fold Feedback Module
for the s88-feedback bus
from the Digital-Professional-Series!
RM-88-N O-F Part-No.: 310102
>> finished module <<
with 16 opto-coupling input connections
(for potential separation and for high interference protection
e.g. contact tracks [one isolated rail], switch tracks or reed-
contacts or turnout feedback reports).
for s88-standard connections and s88-N
(with 6-poles s88-pinbars and RJ-45 sockets).
suitable for the digital control:
Märklin-Digital~/=, Central Station 1 and 2, Intellibox, TWIN-
CENTER, HIS-88(-USB), EasyControl, ECoS, DiCoStation.
This product is not a toy! Not suitable for children under 14 years of age! The kit
contains small parts, which should be kept away from children under 3 years of
age! Improper use will imply danger of injuring due to sharp edges and tips!
Please store this instruction carefully.
CE Part-No.:
24 80 34
Introduction / Safety Information:
You have purchased the feedback module RM-88-N-O for your
digital model railway.
The RM-88-N-O is a high quality product, which is
supplied within the Digital-Professional-Series of Littfinski
DatenTechnik (LDT).
We are wishing you having a good time using this product.
The finished modules come with 24 month warranty.
Please read the following instructions carefully. Warranty will
expire due to damages caused by disregarding the operating
instructions. LDT will also not be liable for any consequential
damage caused by improper use or installation.
Attention: Please switch-off your digital control unit and
unplug all transformers from AC-current before starting
any installation.
General functions:
The feedback module RM-88-N-O contains 16 inputs and is
compatible to the Märklin feedback module s88. The module
contains additionally opto-coupling inputs and is therefore
extremely interference protected. This makes it as well possible
to connect without problems potential bounded contacts,
such as two-rails-two conductor model railway systems.
Connecting the RM-88-N-O to command
stations or interfaces:
Reports of up to 31 feedback modules RM-88-N-O can be
evaluated by a Märklin INTERFACE, Central Station 1 and 2,
Intellibox, TWIN-CENTER, EasyControl, ECoS, HSI-88-
(USB) and DiCoStation.
On each Märklin Memory can be up to 3 feedback modules
RM-88-N-O connected.
All feedback modules will receive the operating current from
the s88-feedback bus. This will apply for s88-standard
feedback module and for the feedback module RM-88-N-O.
If you want to extend your layout with RM-88-N-O feedback
module you can combine those with our feedback module
RM-DEC-88(-Opto), RM-88-N, RM-GB-8(-N) respectively with
s88 feedback module of other manufacturers.
The addresses of the feedback module are related to the
sequence of the connection to the command station
respectively to the interface. The feedback module, which is
directly connected to the central unit, will receive always the
address 1. Further details can be found within the operation
instruction of your command station respectively your
interface.
The feedback module RM-88-N-O contain two 6-poles
pin-bars for the s88-standard connection and as well two
RJ-45 sockets for a bus connection according to
s88-N
. At the
RM-88-N-O are pin-bars and sockets marked with OUT and
IN.
Out indicates the connection in direction to the command
station or interface. IN indicates the connection to the next
following feedback module within the s88-bus line.
Command stations and interfaces are always equipped with
an s88-input for an s88-standard connection.
For the s88-standard connection is an interference
protected twisted s88-bus cable with original s88-bus plugs
available.
The plugs of the s88-bus cable are correct attached onto the
6-poles pin-bar of the RM-88-N-O if the white single wire
corresponds with the white marking on the pc-board next to
the pin-bar.
The direction of the cable has to be directly away from the
feedback module. Additionally attend to the position of the
plugs on the 6-poles pin-bars. No offset will be acceptable.
For the
s88-N
s88-bus connection we offer a screened blue
patch-cable with RJ-45 plugs.
Attention: Command stations with PC-network connection
(e.g. Central Station 1 and 2 and ECoS) contain as well a
RJ-45 socket. It is not acceptable to connect the RM-88-N-O
to the RJ-45 network sockets.
Connection of contacts:
1. Three-conductor rail-system
Switch rails, contact rails and reed-contacts can be
connected to the input clamps 1 to 16 of the feedback module
RM-88-N-O as shown below.

Summary of content (2 pages)