User manual

Littfinski DatenTechnik (LDT)
Operating Instruction
s88-N
16-fold Feedback Module
for the s88-feedback bus
from the Digital-Professional-Series!
RM-88-N-F Part-No.: 310112
>> finished module <<
with 16 input connections, switching against
ground (e.g. for contact tracks [one isolated rail], switch
tracks or reed-contacts).
for s88-standard connections and s88-N
(with 6-poles s88-pinbars and RJ-45 sockets).
suitable for the digital control:
Märklin-Digital~/=, Central Station 1 and 2, Intellibox, TWIN-
CENTER, HSI-88(-USB), EasyControl, ECoS, DiCoStation.
This product is not a toy! Not suitable for children under 14 years of age! The kit
contains small parts, which should be kept away from children under 3 years of
age! Improper use will imply danger of injuring due to sharp edges and tips!
Please store this instruction carefully.
CE Part-No.:
24 80 32
Introduction / Safety Information:
You have purchased the feedback module RM-88-N for your
digital model railway.
The RM-88-N is a high quality product, which is supplied within
the Digital-Professional-Series of Littfinski DatenTechnik
(LDT).
We are wishing you having a good time using this product.
The finished modules come with 24 month warranty.
Please read the following instructions carefully. Warranty will
expire due to damages caused by disregarding the operating
instructions. LDT will also not be liable for any consequential
damage caused by improper use or installation.
Attention: Please switch-off your digital control unit and
unplug all transformers from AC-current before starting
any installation.
General functions:
The feedback module RM-88-N contains 16 inputs, which will
switch against ground. The module is compatible to the Märklin
feedback module s88.
Connecting the RM-88-N to command
stations or interfaces:
Up to 31 feedback modules RM-88-N can evaluate the reports
of a Märklin INTERFACE, Central Station 1 and 2, Intellibox,
TWIN-CENTER, EasyControl, ECoS, HSI-88-(USB) and
DiCoStation.
On each Märklin Memory can be up to 3 feedback modules
RM-88-N connected.
All feedback modules will receive the operating current from
the s88-feedback bus.
If you want to extend your layout with RM-88-N feedback
modules you can combine those with our feedback modules
RM-DEC-88(-Opto), RM-88-N-O, RM-GB-8(-N) respectively
with s88 feedback module of other manufacturers.
The addresses of the feedback modules are related to the
sequence of the connection to the command station
respectively to the interface. The feedback module, which is
directly connected to the central unit, will receive always the
address 1. Further details can be found within the operation
instruction of your command station respectively your
interface.
The feedback module RM-88-N contain two 6-poles pin-bars
for the s88-standard connection and as well two RJ-45
sockets for a bus connection according to
s88-N
. At the RM-88-
N are pin-bars and sockets marked with OUT and IN.
Out indicates the connection in direction to the command
station or interface. IN indicates the connection to the next
following feedback module within the s88-bus line.
Command stations and interfaces are always equipped with
an s88-input for an s88-standard connection.
For the s88-standard connection is an interference
protected twisted s88-bus cable with original s88-bus plugs
available.
The plugs of the s88-bus cable are correct attached onto the
6-poles pin-bar of the RM-88-N if the white single wire
corresponds with the white marking on the pc-board next to
the pin-bar.
The direction of the cable has to be directly away from the
feedback module. Additionally attend to the position of the
plugs on the 6-poles pin-bars. No offset will be acceptable.
For the
s88-N
s88-bus connection we offer a screened blue
patch-cable with RJ-45 plugs.
Attention: Command stations with PC-network connection
(e.g. Central Station 1 and 2 and ECoS) contain as well a RJ-
45 socket. It is not acceptable to connect the RM-88-N to
the RJ-45 network sockets.
s88-N
OUT
IN
s88-N

Summary of content (2 pages)