1.Enter into trigger state display of channels by pressing
2. After entering into PATδΈ(Pat 1) by pressing F2, the existing states of
channels are displayed at lower part of LCD:
The Trigger steps are descried below:
-35-
Pat 1 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
* Initial state: γDon't Careγ.
3. Change the position of cursor to the channel with shuttle, "x" at lower part
of LCD indicates the position of setting.
Press , the setting of channel is changed to "L", namely, trigger at low
logic level(L).
Press , the setting of channel is changed to "H", namely, trigger at high
logic level(H).
Press , the setting of channel is changed to "Don't care", namely, in a
default or neglect state.
Press , the setting of channel is changed to " ", namely, trigger when
low logic level is turned to high logic level.