Enabling Remote Control
Transmitter settings can be configured using special
tones generated by a smartphone using a remote
control application such as Lectro RM (available on the
AppStore or Google Play). Enable this feature on the
transmitter with the following menu items.
BatType
Remote
TxPow er
Default
Remote
Enable
Ignore
The following settings can be configured:
Tx Input Gain
• Sleep/Unsleep
• Lock/Unlock
Tx power output
• Frequency
Setting Transmitter Output Power
The output power can be set to 50 mW or 100 mW.
BatType
Remote
TxPow er
Default
TxPower
50 mW
100 mW
Restoring Default Settings
This is used to restore the factory settings.
BatType
Remote
TxPow er
Default
Default
settings
No
Ye s
IR Sync Operation
A Lectrosonics receiver with IR Sync capability can
transfer the settings for Frequency, Step Size and Com-
patibility mode to the transmitter via the IR ports. The
transfer is triggered by a switch in the receiver. When
the settings are successfully transferred, a confirmation
will appear on the transmitter LCD.
IR Sync
OK
If a mismatch exists and the transfer cannot be com-
pleted, an error message will appear on the transmitter
LCD indicating what the problem is.
IR Sync
BLOCK
Mismatch
IR Sync
COMPAT
Mismatch
BLOCK Mismatch indicates that the transmitter and
receiver are on different frequency blocks and the
frequency cannot be set to match. COMPAT Mismatch
will appear when the compatibility mode in the receiver
is not available in the transmitters; for example, when
you are trying to sync a US model to work an export
model.