Push buttons
The S1 push button is used for a hard-reset purpose; a short press resets the module.
The S3 push button is used for special purposes (refer to Table 4).
Table 4: S3 push button functionalities
Description
Action
Long press during module
operation (longer than 10
seconds)
Resets the carrier board configuration to the default values:
CAN port configuration
1Mbsp, standard frame format
Base Rx: 0x740
Base Tx: 0x750
No delay
Distance in cm and a max. of 96 echoes
Serial link configuration
115,200 bps, 8 bits, no parity, no flow control, 1 stop bit
Distance in cm and a max. of 40 echoes
Modbus address: 1
Press the S3 button for
more than 2 seconds
during startup (or after a
hard reset)
Put the USB, CAN and SERIAL carrier board in bootloader mode. This
feature is used to upgrade the USB, CAN and SERIAL carrier board
firmware.
Use the LeddarTech software tool to upgrade firmware.