LeddarVu User Guide Page 42 of 129
4.4. Measurement Rate
The LeddarVu module acquires a base input waveform for all segments at a rate between 10 kHz
and 40 kHz, depending on the sensor field of view (see Table 11).
Multiple acquisitions are used to perform accumulations and oversampling and generate a final
waveform that is then processed to detect the presence of objects and measure their position.
Table 11: Base Acquisition Rate Based on the Field of View
LeddarVu8 FOV
Base Acquisition Rate
16°
10 kHz
47.5°
20 kHz
98.5°
40 kHz
Therefore, the final measurement rate is:
𝑀𝑒𝑎𝑠𝑢𝑟𝑒𝑚𝑒𝑛𝑡 𝑟𝑎𝑡𝑒 =
𝐵𝑎𝑠𝑒 𝑅𝑎𝑡𝑒
(
𝑁𝑢𝑚𝑏𝑒𝑟 𝑜𝑓 𝑠𝑒𝑔𝑚𝑒𝑛𝑡𝑠 𝑒𝑛𝑎𝑏𝑙𝑒𝑑 + 1
)
𝑎𝑐𝑐𝑢𝑚𝑢𝑙𝑎𝑡𝑖𝑜𝑛𝑠 𝑜𝑣𝑒𝑟𝑠𝑎𝑚𝑝𝑙𝑖𝑛𝑔
For example, LeddarVu 16° with 256 accumulations and an oversampling value of 8:
𝑀𝑒𝑎𝑠𝑢𝑟𝑒𝑚𝑒𝑛𝑡 𝑟𝑎𝑡𝑒 =
10000
(
8 + 1
)
256 8
= 0.5425 Hz
Table 12 below presents the measurement rate for typical values of accumulations and
oversampling.