Set CAN port settings (function code 0x45, 0x05)
Table 51 and Table 52 present the requests and answers for the CAN port commands.
Table 51: Requests header field
Offset
Length
Description
0
1
Sub-function code: 0x05
Table 52: Requests CAN port settings field
Offset
Length
Description
0
1
Settings of corresponding logical CAN port number to set
1
4
Baud rate, supported rates:
10,000
20,000
50,000
100,000
125,000
250,000
500,000
1,000,000
5
1
Frame format:
0 = Standard 11 bits
1 = Extended 29 bits
6
4
Tx base ID
10
4
Rx base ID
14
1
Maximum number of detections (measurements) returned per
CAN detection message transaction: 1 through 96
15
2
Distance resolution:
1 = m
10 = dm
100 = cm
1,000 = mm
17
2
Inter-message delay 0 through 65535 milliseconds
19
2
Inter-cycle delay 0 through 65535 milliseconds