Important Information and Precautions
z The PowerStar’s LED, when powered up, is very powerful. Although the light may appear off, however IR is invisible
to the human eye and can still damage eyes. Thus it is advised that you do not look directly at it. Turn the PowerStar
away.
z PowerStars will overheat in operation if not attached to a suitable Heatsink. Overheating can cause failure or
irreparable damage.
z Do not operate PowerStars with a Power Supply with unlimited current. Connection to constant voltage Power
Supplies that are not current limited may cause the PowerStar to consume current above the specified maximum and
cause failure or irreparable damage.
z PowerStars, when operated, can reach high temperatures thus there is risk of injury if they are touched.
z DO NOT HOT PLUG ON LED SIDE OF POWER SUPPLY
z DO NOT TOUCH or PUSH on the LED as this might cause irreparable damage.
Product Options
ILS PART NUMBER IR centroid wave-
length*
Radiant intensity
IF = 1 A , tp = 10 ms
Forward
Voltage
Radiance
Angle
Relevant OSRAM
LED Data
ILH-IS01-85SN-SC201-
WIR200.
850nm Stack 370mW/sr 3.00-3.60V ±60° (120°) SFH4770S
ILH-IS01-94SN-SC201-
WIR200.
940nm Stack 360mW/sr 3.00-3.60V ±60° (120°) SFH4775S
*Due to the special conditions of the manufacturing processes of LEDs, the typical data of technical parameters can only reflect statistical figures and do not
necessarily correspond to the actual parameters of each single product which could differ from the typical data.
§ Tolerance +/- 10%
† Measured with 700mA pulse at 25˚c
Minimum and Maximum Ratings
ILS PART NUMBER Operating Temperature
at Tc-Point [˚C]*
Storage
Temperature [˚C]*
Forward Current
per chip [mA]*
Surge
Current
Reverse Voltage
ILH-IS01-85SN-SC201-
WIR200.
-40 ... 125°C -40 ... 125°C 1500mA 3000mA Not designed for
reverse operation
ILH-IS01-94SN-SC201-
WIR200.
-40 ... 125°C -40 ... 125°C 1500mA 3000mA Not designed for
reverse operation
* Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED module.
Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED module.
The temperature of the LED module must be measured at the Tc-Point according to EN60598-1 in a thermally constant status with a temperature sensor or a
temperature sensitive label.