Datasheet

www.i-led.co.uk
Intelligent LED Solutions, Unit 2, Berkshire Business Centre, Berkshire Drive, Thatcham, Berkshire, RG19 4EW
Telephone : +44 (0)1635 294606 Email: info@i-led.co.uk Website: www.i-led.co.uk
A division of Intelligent Group Solutions Ltd
2
© IGS Version V3.1 May 2019
Important Information and Precautions
z The PowerStars’s LED, when powered up, is very powerful although the light may appear off. IR is invisible to the
human eye but, can still damage eyes. Thus it is advised that you do not look directly at it. Turn the PowerStar away
from you and do not shine into the eyes of others.
z PowerStars will overheat in operation if not attached to a suitable Heatsink. Overheating can cause failure or
irreparable damage.
z Do not operate PowerStars with a Power Supply with unlimited current. Connection to constant voltage Power
Supplies that are not current limited may cause the PowerStar to consume current above the specified maximum and
cause failure or irreparable damage.
z PowerStars, when operated, can reach high temperatures thus there is risk of injury if they are touched.
z DO NOT TOUCH or PUSH on the LED as this can cause irreparable damage.
z DO NOT HOT PLUG ON LED SIDE OF POWER SUPPLY.
Product Options
ILS Part Number IR centroid
wavelength
nm
Radiant Intensity*
IF=1A,
tp= 10 ms mW/sr
Forward Voltage
(IF= 0.5A,tp
= 100 µs)§
Radiance Angle Relevant OSRAM
IR Data Sheet
ILH-IX01-81SL-SC201-
WIR200.
810nm
2900mW/sr
Total Radiant Flux
680mW
3.3 Volts
±1 SFH 4780S
ILH-IX01-81SL-SC211-
WIR200.
810nm 1330mW/sr
Total Radiant Flux
780mA
3.3-3.6 Volts ±15° (30°) SFH4786S
ILH-IX01-81SL-SC212-
WIR200.
810nm 1000mW/sr
Total radiant flux
720mW
3.3-3.6 Volts ±15° (30°) SFH4787S
*Due to the special conditions of the manufacturing processes of LEDs, the typical data of technical parameters can only reflect statistical figures and do not
necessarily correspond to the actual parameters of each single product which could differ from the typical data.
§ Tolerance +/- 10%
F = 1000 mA; tp = 10 ms; TA = 25 °C
Minimum and Maximum Ratings
ILS Part Number Operating
Temperature at Tc-
Point [˚C]*
Storage
Temperature
[˚C]*
Maximum Current
per chip [mA]*
Surge Current
per chip [mA]*
Reverse
Voltage [Vdc]*
ILH-IX01-81SL-SC201-
WIR200.
-40 to 85 °C -40°C to + 125°C 500mA 2000mA not desigined for
reverse operation
ILH-IX01-81SL-SC211-
WIR200.
-40 to 85 °C -40°C to + 125°C 500mA 2000mA not desigined for
reverse operation
ILH-IX01-81SL-SC212-
WIR200.
-40 to 85 °C -40°C to + 125°C 500mA 2000mA not desigined for
reverse operation
*Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED module. Exceeding maximum ratings for
operating voltage will cause hazardous overload and will likely destroy the LED module. The temperature of the LED module must be measured at the Tc-Point
according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label.
DATASHEET