Thermal Interface Material Options
ILS have produced a range of High-performance, cost effective Thermal Interface Materials to match perfectly their
standard products.
Our product fills the air pockets between the two surfaces, forming a continuous layer to conduct heat away from the
LED to the Heat Sink.
ILS offer our TIM in three options – double sided adhesive, single sided adhesive and non adhesive.
Product Non Adhesive Single Sided Adhesive Double Sided Adhesive
Star
ILA-TIM-STAR-0A ILA-TIM-STAR-1A ILA-TIM-STAR-2A.
25x25mm Cluster ILA-TIM-CLUSTER-25x25-0A ILA-TIM-CLUSTER-25x25-1A ILA-TIM-CLUSTER-25x25-2A.
30x30mm Cluster ILA-TIM-CLUSTER-30x30-0A ILA-TIM-CLUSTER-30x30-1A ILA-TIM-CLUSTER-30x30-2A.
300x20mm Strip ILA-TIM-STRIP-300x20-0A ILA-TIM-STRIP300x20-1A ILA-TIM-STRIP-300x20-2A.
25x15mm Strip ILA-TIM-STRIP-25x15-0A ILA-TIM-STRIP-25x15-1A ILA-TIM-STRIP-25x15-2A.
58x58mm Square ILA-TIM-SQUARE-58X58-0A ILA-TIM-SQUARE-58X58-1A ILA-TIM-SQUARE-58X58-2A.
Other sizes are available, including customised parts
Assembly Information
z The mounting of the OSLON
®
80 4+ PowerStar has to be on a metal Heat Sink.
z In order to optimise the thermal management, the metal surface needs to be clean (dirt and oil free) and planar for
the best contact with the LED module. A thermal grease or heat transfer material is highly recommended.
Safety Information
z The LED module itself and all its components must not be mechanically stressed.
z Assembly must not damage or destroy conducting paths on the circuit board.
z The mounting of the module is carried out by attaching it at the mounting holes. Metal mounting screws must be
insulated with synthetic washers to prevent circuit board damage and possible short circuiting.
z To avoid mechanical damage to the connecting cables, the boards should be attached securely to the intended
substrate. Heavy vibration should be avoided.
z Observe correct polarity!
z Depending on the product, incorrect polarity will lead to emission of red or no light. The module can be destroyed!
z Pay attention to standard ESD precautions when installing the OSLON
®
80 4+ PowerStar.
z The OSLON
®
80 4+ PowerStars, as manufactured, have no conformal coating and therefore offer no inherent
protection against corrosion.
z Damage by corrosion will not be accepted as a materials defect claim. It is the user’s responsibility to provide
suitable protection against corrosive agents such as moisture and condensation and other harmful elements.
z For outdoor usage, a housing is definitely required to protect the board against environmental influences. The
design of the housing must correspond to the IP standards in the application. It is also the responsibility of the user
to ensure any housings or modifications keep the Tc junction temperature to within stated ranges.
z To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the
CE mark and be ENEC certified. In Europe the declarations of conformity must include the following standards: CE:
EC 61374-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61374-2-13 and IEC/EN 62384.