Data Sheet

DULUX
®
S/E & QUICKTRONIC
®
Edition 01.2014. Subject to change without notice. Errors and omissions excepted.Always make sure to use the most recent
release.
LP LPD MK
TECHNICAL INFORMATION 03
Electrical Data
2
Lamps operated with HF
3
reference control gear at 25 °C (100 h aged) ambient temperature
DULUX
®
S/E
Lamp Voltage rated
[V]
Lamp Current rated
[mA]
Lamp Power rated
[W]
7 W
37
175
6.5
9 W
48
170
8.0
11 W
75
150
11.0
Photometrical Data at 25 °C (100 h aged) ambient temperature
4
DULUX
®
S/E
Light Color
LUMILUX
®
Color
Rendering
Index (CRI),
Ra
Lumi-nance
(LC
5
840)
[cd/cm²]
Target
Color
Coordinate
X
Target Color
Coordinate
Y
Nominal
Luminous
Flux
[lm]
Efficacy
25 °C
[lm/W]
7 W
827 INTERNA
80 … 89
2.6
0.455
0.415
400
62
7 W
830 Warm White
80 … 89
2.6
0.440
0.403
400
62
7 W
840 Cool White
80 … 89
2.6
0.380
0.380
400
62
9 W
827 INTERNA
80 … 89
2.8
0.455
0.415
600
75
9 W
830 Warm White
80 … 89
2.8
0.440
0.403
600
75
9 W
840 Cool White
80 … 89
2.8
0.380
0.380
600
75
11 W
827 INTERNA
80 … 89
2.7
0.455
0.415
900
82
11 W
830 Warm White
80 … 89
2.7
0.440
0.403
900
82
11 W
840 Cool White
80 … 89
2.7
0.380
0.380
900
82
2
According to IEC 60901
3
High Frequency
4
Measurement in accordance with IEC 60901, annex C and the relevant annex on rated colour characteristics in IEC 60081.
5
Light Color