Wake Up Interval Capabilities Report CC
Parameter
Value
WAKEUP_PAR_DEFAULT_SLEEP_TIME
0x0E10
WAKEUP_PAR_MAX_SLEEP_TIME
0x28DE80
WAKEUP_PAR_MIN_SLEEP_TIME
0x3C
WAKEUP_PAR_SLEEP_STEP
0x3C
Manufacturer Specific Report
Parameter
Value
Manufacturer ID 1
0x03
Manufacturer ID 2
0x00
Product Type ID 1
0x03
Product Type ID 2
EU
0x00
NA
0x01
Product ID 1
0x00
Product ID 2
0x26
Configuration Set Command Class
Command Format
7
6
5
4
3
2
1
0
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Parameter Number
Default
Reserved
Size
Configuration Value 1(MSB)
Configuration Value 2
……
Configuration Value n(LSB)
Parameter Number Definitions (8 bit)
Parameter
Number
Description
Default
Value
Size
0x0A (10)
Low battery power level of alarm threshold values: the
value range are 0~50 for percentage, the battery low
power level can setting 0%~50%.
0x0A
1