Quick Start Guide

8
Motion is
triggered
In the network: Send Notification report and Sensor multilevel report
and Basic set (Setup configuration parameter 0x0E to 0x01), and the
LED will be blink 0.5 second.
Not in the network: NOP.
Tamper switch is
triggered
In the network: Send Notification report, and the LED will be blink 0.5
second.
Not in the network: Only the LED will be blink 0.5 second.
6.2 Caution:
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
Hereby, Corporation declares that this device is in compliance with the essential requirements and other
relevant provisions of Directive 2014/53/EU
6.3 Low voltage alarm to remind changing battery.
This product has low voltage detection reminder, when the battery voltage is in low status, the
detector will give out low battery signal to controller.
6.4 Z-Wave command.
Special Rule Of Each Command Class
Z-Wave Plus Info Report Command Class
Parameter
Value
Z-Wave Plus Version
0x01
Role Type
0x06
(ZWAVEPLUS_INFO_REPORT_ROLE_TY PE_SLAV E_SLEEPING_REPOR
TING)
Node Type
0x00 (ZWAVEPLUS_INFO_REPORT_NODE_TY PE_ZWAV EPLUS_NODE)