Installation Guide

10
9. When the Fire Pit is not in use and has cooled completely, cover with the
Vinyl Fire Pit Cover. CAUTION: Never place the cover on a HOT Fire Pit.
Fire Pit must be cooled completely before covering.
10
. Connect hose and regulator to cylinder. The propane gas and cylinder are
sold separately. Use a standard 20 lb. propane cylinder only. Use this fire pit
only with a vapor withdrawal supply system. See Chapter 5 of the standard for
storage and handling of liquefied petr
oleum gas, ANSI/NFPA 58. Your local
library or fire department should have this book.
Storage of an appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance. A cylinder must be stored
outdoors in a well-ventilated area out of reach of children. A disconnected
cylinder must have all dust caps tightly installed and must not be stored in a
building, garage or any other enclosed area. The maximum inlet gas supply
pressure: 250 psi.
The minimum inlet gas supply pressure: 5 psi.
The minimum hourly rate of 10000 Btu is required input rating for a fire pit
for automatic operation at rating less than full input rating.
The pressure regulator and hose supplied with the appliance must be used.
The installation must confirm with local codes or in the absence of local codes,
with national fuel gas code, ANSI Z223.1/NFPA54, natural gas and propane
Installation Code, CSA B149.1, or propane storage and handling code, B14
9.2.
ASSEMBLY
9